SIGNAL INPUT, module ME

OVERVIEW

This module together with the "MP" input board, performs the signal input conditioner (see Fig. 2). This module contains the trimmers and jumpers for the amplifier gain and the low level output (offset).

The signal input connections are made at Terminals 3, 4, 5 and 6. Each signal type use some of these terminals.

FIG.7

 

1

 

P1

2

P2

 

 

P1 : Output zero adjustment.

P2 : Gain amplifier adjustment.

B

A

C

Solder pads on solder side

OFFSET ADJUST

Solder pad 1 if closed : Adjust the low range level of the output (Offset positive coarse).

Solder pad 2 if closed : Adjust the low range level of the output (Offset negative coarse).

Jumper A if closed : Adjust the low range level of the output (Offset negative fine).

AMPLIFIER GAIN

 

Jumper B if closed

: Gain at maximum level

Jumper C if closed

: Gain at medium level.

Jumpers B and C opened

: Gain at minimum level.

6

Image 7
Contents User’sGuide Omega.comTM Table of Contents Internal Overview Open the HousingProcedure Procedure for DisassemblyProtections Recomended WiringPrecautions Changing the Power SupplyNON Standard Output Voltages Currents Changing the Signal OutputOverview Offset AdjustAmplifier Gain Input CCT-05 Electrical FeaturesGeneral Specifications Sensor Type SelectionAdjustment and Calibration Procedure Signal Input Range SelectionConnections Signal OutputTechnical Data DimensionsMechanical Page USAWARRANTY/DISCLAIMER Temperature