Programming Control
16.Slow Drain Detection Adjust “SdAd”
This option allows the owner to increase or decrease the slow drain detection threshold by adding additional seconds to the threshold value. When enabled it increases the time before a Slow Drain Error will occur.
How to Program the Pause/Resume Mode
1.Control must be in Manual Mode. Refer to Entering the Manual Mode.
2.Press the #3 (>) or the #6 (<) keypad until
“Prog” appears in the display. Press the START (enter) keypad and “dCYC” will appear in the display.
3.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable options until “SdAd” appears in the display.
4.When “SdAd” appears in the display, press the START (enter) keypad. The current Slow Drain Detection Adjust Value will appear in the display. “on” = Option Enabled
“oFF” = Option Disabled
5.Press the #3 (>) or the #6 (<) keypad to change the current value.
6.Press the START (enter) keypad when the desired value appears in the display. The next option, “rtc”, will appear in the display.
NOTE: To program “rtc” (Set
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to Start Mode.
36 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F8208801 |