Programming Control

Manual Programming Flowchart (3 of 3)

(continued)

“bALr” (VFD only) - Program the number of times control will retry balancing the load before moving to extract step: 1-7.

“IrA” - Enable/disable the ability to read

the control by an external device:

“on” = Enabled “off” = Disabled.

“t FC” (Temp Sensor only) - Set

temperature shown in Fahrenheit or Celsius.

“FH” (Temp Sensor only) - Set the temperature of the hot water: 35°F - 194°F / 2°C - 90°C.

“FHC” (Temp Sensor only) - Set the

temperature of the warm water:

35°F - 194°F / 2°C - 90°C.

“FC” (Temp Sensor only) - Set the

temperature of the cold water:

35°F - 194°F / 2°C - 90°C.

“Codn” (Temp Sensor only) - Enable/disable the cool down water temperature option:

“off” or 50°F - 160°F / 10°C - 71°C.

“PtEn” - Enable/disable access to the

production test cycle:

“on” = Enabled “off” = Disabled.

“rAEn” - Enable/disable the rapid advance

feature:

“on” = Enabled “off” = Disabled.

“nCtd” - Enable/disable whether the cycle

time will appear in display:

“on” = Enabled “off” = Disabled.

“PCtd” * - When enabled, the control displays the programmed time during a machine cycle:

“0” = Disabled “1” = Enabled

“SdAd” - Enable/disable slow drain

detection. When enabled can

increase/decrease the time before a slow

drain error will occur:

0 - 255 seconds

“rtC-” - set the control’s internal clock.

“dAEn” - Enable/disable the manual

diagnostics option:

“on” = Enabled “off” = Disabled.

“FLo” - Program the low water level during fill and tumble of all cycles:

“1” - “10”

“FnEd” - Program the medium water level

during fill and tumble of all cycles:

“11” - “20”

“FHI” - Program the high water level during

fill and tumble of all cycles:

“21” - “30”

“tCF” (Temp Sensor only) - Enable/disable a

temperature controlled fill:

“on” = Enabled “off” = Disabled.

“ALd-” - Set the time and frequency that the control automatically checks the water level.

* Option available on software version 2 only.

Temperature:

“CEL” = Celsius

“FAHr” = Fahrenheit

“rtC1” - Programs minutes:

“0” - “59”

“rtC2” - Programs Hours:

“0” - “23”

“rtC3” - Programs Day of Week:

“1” - “7”

“rtC4” - Programs Date of Month:

“1” - “31”

“rtC5” - Programs Month:

“1” - “12”

“rtC6” - Programs Year:

“0” - “99”

“rtC7” - Programs Daylight Saving:

“on” = Enabled

“oFF” = Disabled

“ALd1” - Auto-Water Leak Detection:

“on”, then “0” - “127”

“oFF”

“ALd2”” - Auto-Water Leak Detection

Hour:

“0” - “23”

“ALd3” - Auto-Water Leak Detection

Day of Week:

“0” - “127”

PHM1400R

PHM1400R

Figure 5

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

17

Page 19
Image 19
Alliance Laundry Systems PHM1263R manual Manual Programming Flowchart 3, Option available on software version 2 only