3.Error Code Programming “Err-”
This option allows the owner to turn on or turn off certain errors in the control.
How to Program Error Code Programming
1.Control must be in Manual Mode. Refer to Entering the Manual Mode.
2.Press the #3 (>) or the #6 (<) keypad until
“Prog” appears in the display. Press the START (enter) keypad and “dCYC” will appear in the display.
3.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable options until
4.When
5.Press the #3 (>) or the #6 (<) keypad to select error code.
6.Press the START (enter) keypad when the correct code appears in the display. The current status will appear in the display.
“on” = Error Code Enabled “oFF” = Error Code Disabled
7.Press the #3 (>) or the #6 (<) keypad to change the status.
8.Press the START (enter) keypad when the correct status appears in the display. The next Error Code Programming option will appear in the display.
NOTE: To program
How to Exit Programming Feature
9.Press the #5 (<) keypad until the control returns to Start Mode.
“E FL” | Fill Error |
|
|
|
| ||
“E dr” | Drain Error | ||
|
| ||
“E Ub” | Unbalance Error Display (VFD only) | ||
|
| ||
“E oP” | Open Thermistor Error Display | ||
|
| ||
“E SH” | Shorted Thermistor Error Display | ||
|
| ||
“E Ht” | Heat Error Display (Heater only) | ||
|
| ||
Leak Detection Error | |||
| If water leak detection during a machine | ||
| cycle is enabled, then, on the enabled day(s) | ||
| of the week, the control will check for water | ||
| leaks during running machine cycles. If a | ||
| leak is detected, the control will display the | ||
| “E Ld” error for one minute after the cycle | ||
| is completed. It will also light the | ||
| decimal point on the display. To turn off the | ||
| |||
| press the START keypad 3 times (within 5 | ||
| seconds) anytime after the first fill. The | ||
| water leak detector diagnostic test can be | ||
| used to verify the leak. | ||
|
|
|
|
|
|
| Water Leak Detection During |
| “LEr1” |
| a Machine Cycle - Determines |
|
| if water level drops below | |
|
|
| |
|
|
| target level. |
|
|
|
|
|
|
| Water Leak Detection During |
|
|
| Machine Cycle Day of Week |
| “LEr2” |
| Enable (Refer to Figure 3 for |
|
|
| Day(s) of the Week Enabled |
|
|
| Values) |
|
|
|
|
|
|
| Number of Cycles Between |
|
|
| Water Leak Detection During |
| “LEr3” |
| a Machine Cycle (Option not |
|
|
| available on Software |
|
|
| Version 1.) |
|
|
| |
“ESd” | Slow Drain Detection Determines if | ||
| machine is draining slower than normal. | ||
| If Slow Drain Detection is enabled, the | ||
| control will check for slow drain operation | ||
| during running machine cycles. If a slow | ||
| drain is detected, the control will display the | ||
| “ESd” error for one minute after the cycle is | ||
| completed. It will also light the | ||
| decimal point on the display. For machines | ||
| equipped with Software Version 2, to turn | ||
| off the | ||
| display, press the START keypad 3 times | ||
| (within 5 seconds) anytime after the first fill. | ||
|
|
|
|
|
| Table 3 |