Programming Control

3.Error Code Programming “Err-”

This option allows the owner to turn on or turn off certain errors in the control.

How to Program Error Code Programming

1.Control must be in Manual Mode. Refer to Entering the Manual Mode.

2.Press the #3 (>) or the #6 (<) keypad until

Prog” appears in the display. Press the START (enter) keypad and “dCYC” will appear in the display.

3.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable options until Err- appears in the display.

4.When Err- appears in the display, press the START (enter) keypad. Refer to Table 3 for a list of programmable error code parameters.

5.Press the #3 (>) or the #6 (<) keypad to select error code.

6.Press the START (enter) keypad when the correct code appears in the display. The current status will appear in the display.

on” = Error Code Enabled “oFF” = Error Code Disabled

7.Press the #3 (>) or the #6 (<) keypad to change the status.

8.Press the START (enter) keypad when the correct status appears in the display. The next Error Code Programming option will appear in the display.

NOTE: To program “Cy--”(Cycle Programming), press the #5 (<) keypad, then the #3 (>) keypad and refer to option 4. To program other options, refer to the appropriate section.

How to Exit Programming Feature

9.Press the #5 (<) keypad until the control returns to Start Mode.

“E FL”

Fill Error

 

 

 

 

“E dr”

Drain Error

 

 

“E Ub”

Unbalance Error Display (VFD only)

 

 

“E oP”

Open Thermistor Error Display

 

 

“E SH”

Shorted Thermistor Error Display

 

 

“E Ht”

Heat Error Display (Heater only)

 

 

“LEr-”

Leak Detection Error

 

If water leak detection during a machine

 

cycle is enabled, then, on the enabled day(s)

 

of the week, the control will check for water

 

leaks during running machine cycles. If a

 

leak is detected, the control will display the

 

E Ld” error for one minute after the cycle

 

is completed. It will also light the right-most

 

decimal point on the display. To turn off the

 

right-most decimal point on the display,

 

press the START keypad 3 times (within 5

 

seconds) anytime after the first fill. The

 

water leak detector diagnostic test can be

 

used to verify the leak.

 

 

 

 

 

 

 

Water Leak Detection During

 

“LEr1”

 

a Machine Cycle - Determines

 

 

if water level drops below

 

 

 

 

 

 

target level.

 

 

 

 

 

 

 

Water Leak Detection During

 

 

 

Machine Cycle Day of Week

 

“LEr2”

 

Enable (Refer to Figure 3 for

 

 

 

Day(s) of the Week Enabled

 

 

 

Values)

 

 

 

 

 

 

 

Number of Cycles Between

 

 

 

Water Leak Detection During

 

“LEr3”

 

a Machine Cycle (Option not

 

 

 

available on Software

 

 

 

Version 1.)

 

 

 

“ESd”

Slow Drain Detection Determines if

 

machine is draining slower than normal.

 

If Slow Drain Detection is enabled, the

 

control will check for slow drain operation

 

during running machine cycles. If a slow

 

drain is detected, the control will display the

 

ESd” error for one minute after the cycle is

 

completed. It will also light the right-most

 

decimal point on the display. For machines

 

equipped with Software Version 2, to turn

 

off the right-most decimal point on the

 

display, press the START keypad 3 times

 

(within 5 seconds) anytime after the first fill.

 

 

 

 

 

 

Table 3

22

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208801

Page 24
Image 24
Alliance Laundry Systems PHM1263R manual Error Code Programming Err, How to Program Error Code Programming, LEr3, ESd