20. Medium Water Level “FnEd”

This option allows the owner to program the medium water level during fill and tumble of all cycles.

How to Program Medium Water Level

1.Control must be in Manual Mode. Refer to Entering the Manual Mode.

2.Press the #3 (>) or the #6 (<) keypad until

Prog” appears in the display. Press the START (enter) keypad and “dCYC” will appear in the display.

3.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable options until “FnEd” appears in the display.

4.When “FnEd” appears in the display, press the START (enter) keypad. A number will appear in the display. This number corresponds to the current medium water level during tumble and fill of all cycles.

5.Press the #3 (>) or the #6 (<) keypad to increase or decrease the current water level to the desired water level.

NOTE: The Medium Water Level value can be set from 11 to 20.

6.Press the START (enter) keypad when the correct number appears in the display. The next option, “FHI”, will appear in the display.

NOTE: To program “FHI” (High Water Level), refer to option 21. To program other options, refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to Start Mode.

Programming Control

21. High Water Level “FHI”

This option allows the owner to program the high water level during fill and tumble of all cycles.

How to Program High Water Level

1.Control must be in Manual Mode. Refer to Entering the Manual Mode.

2.Press the #3 (>) or the #6 (<) keypad until

Prog” appears in the display. Press the START (enter) keypad and “dCYC” will appear in the display.

3.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable options until “FHI” appears in the display.

4.When “FHI” appears in the display, press the START (enter) keypad. A number will appear in the display. This number corresponds to the current high water level during tumble and fill of all cycles.

5.Press the #3 (>) or the #6 (<) keypad to increase or decrease the current water level to the desired water level.

NOTE: The High Water Level value can be set from 21 to 30.

6.Press the START (enter) keypad when the correct number appears in the display. The next option, “tCF”, will appear in the display.

NOTE: To program “tCF” (Temperature Controlled Fill), refer to option 22. To program other options, refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to Start Mode.

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT