Error Codes

Following is a list of possible error codes for an electronic control. Errors beginning with “EI” refer to external device Infra-red communication errors. All other errors refer to machine errors.

Display

Description

 

Cause/

 

Corrective Action

 

 

 

 

 

 

 

EI01

Transmission Failure

 

Communication failure. Re-aim external device and try again.

 

 

 

 

EI02

Time-out Error

 

Communication failure. Re-aim external device and try again.

 

 

 

 

EI03

Invalid Command Code

 

Communication successful, but the command was not valid

 

 

 

for this machine type, or the control could not perform the

 

 

 

command in its current mode of operation. Ensure data is for

 

 

 

current machine type and control is in correct mode.

 

 

 

 

EI04

Expecting Upload Request

 

Communication failure. Re-aim external device and try again.

 

 

 

 

EI05

Invalid or Out-of-Range Data

 

The value in at least one of the programming options is

 

 

 

invalid or out of range. Recheck the programming option’s

 

 

 

value and try again.

 

 

 

 

EI09

CRC-16 Error

 

Communication failure. Re-aim external device and try again.

 

 

 

 

EI0A

Framing Error

 

Communication error. Re-aim external device and try again.

 

 

 

 

EI0C

Time-out Exceeded

 

Communication error. Re-aim external device and try again.

 

 

 

 

EI0E

Encryption Error

 

Communication error. Re-aim external device and try again.

 

 

 

If the problem persists, check that the security code is correct.

 

 

 

 

EI0F

Infra-red Disabled

 

Communication failure or infra-red is disabled. Manually

 

 

 

enable infra-red on control or re-aim external device and try

 

 

 

again.

 

 

 

 

E FL

Fill Error

 

Programmed water level not reached within 10 minutes (or

 

 

 

other programmed length of time) in any fill agitate cycle.

 

 

 

End cycle. Power down machine to clear.

 

 

 

 

E SP

SPI Communications Error

 

Front End control cannot communicate with output board.

 

 

 

Power down the machine, power up and try again.

 

 

 

 

 

 

Table 16 (continued)

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

51

Page 53
Image 53