Programming Control

Diagnostic Tests Flowchart

“dIAg” - Diagnostic Tests.

1. Press START (enter) keypad.

“d001” - Front End Control

Software Version # Test

“S xx”

“d002” - Output Board Control

Software # Test

“o xx”

“d003” - Output Board Water Level

Sensor Trim Value

“txxx”

“d004” - Top Cover Opening Test

“A oP” or “A CL”

“d009” - Door Switch Input Test

“drCL” or “drOP”

“d010” - Door Lock Input Test

“drUL” or “drLo”

“d011” - Show Fill Time Test

“Fxxx”

“d012” - Show Drain Time Test

“dxxx”

“d013” - Termperature Sensor

Display Test

“xxxF” or “xxxC”

“d014” - Start Pulse Test

“Stxx”

“d015” - VFD Balance Input Test

“bAoP” or bACL”

“d016” - 24 VAC Switch Input Test

“ACoP” or “ACCL”

“d017” - VFD Drive Fault Input

Test

“dFoP” or “dFCL”

“d018” - Frame Balance Switch

Input Test

“FSoP” or “FSCL”

“d019” - VFD Balance Weight Test

“bAL”

“d020” - Water Purge Test

“PUrg”

“d021” - Water Leak Detection

Test

“Ld”

PHM1283R

Figure 6

18

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208801

Page 20
Image 20
Alliance Laundry Systems PHM1263R manual Diagnostic Tests Flowchart