Programming Control

Programming Supply Step

1.When “SUPL” appears in the display, press the START (enter) keypad. The first Supply step programming option will appear in the display.

2.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable Supply step options. Refer to Table 7.

NOTE: Supply Step “SUEn” must be enabled to scroll through all Supply Step options.

3.Press the START (enter) keypad when the desired option appears in the display. The current status value will appear in the display. Refer to Table 7.

Supply

Description

Status/Value

Step

 

 

 

 

 

“SUEn”

Supply Step

“on”/“oFF”

 

Enable/Disable

 

 

 

 

“dISP”

Dispenser Options

Press START (enter) to

 

 

access options

 

 

 

“S1”

Supply #1

“on”/“oFF”

 

 

 

“S2”

Supply #2

“on”/“oFF”

 

 

 

“S3”

Supply #3

“on”/“oFF”

 

 

 

“S4”

Supply #4

“on”/“oFF”

 

 

 

“SdUr”

Supply Duration

Press START (enter)

 

 

to access options

 

 

 

“SEC”

Seconds

0-59

 

 

 

“nIn”

Minutes

0-9

 

 

 

 

Table 7

 

4.Press the #3 (>) or the #6 (<) keypad to change the current status/value.

5.Press the START (enter) keypad when the desired status/value appears in the display. The next Supply step option will appear in the display.

NOTE: To program “AgSt” (Agitate Step), continue to next Cycle Segment option. If in the Dispenser Options or Supply Duration programming option, press the #5 (<) keypad first. To program other options, press the #3 (>) or the #6 (<) keypad and refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to Ready Mode.

Programming Agitate Step

1.When “AgSt” appears in the display, press the START (enter) keypad. The first Agitate step programming option will appear in the display.

2.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable Agitate step options. Refer to Table 8.

NOTE: Agitate Step “AgEn” must be enabled to scroll through all Agitate step options.

3.Press the START (enter) keypad when the desired option appears in the display. The current status/value will appear in the display. Refer to Table 8.

Agitate

Description

Status/Value

Step

 

 

 

 

 

“AgEn”

Agitate Step

“on”/“oFF”

 

Enable/Disable

 

 

 

 

“AdUr”

Agitate Duration

1-30 Minutes for

 

(in minutes)

agitate types 1 or 2

 

 

1-180 Minutes for

 

 

agitate types 3 or 4

 

 

(Refer to Cycle Agitate)

 

 

 

“HEAt”

Heat in Agitate

“oFF”, 1 or 2

 

(If heater is present)

1 = To Target

 

 

2 = Maintain

 

 

 

 

Table 8

 

4.Press the #3 (>) or the #6 (<) keypad to change the current status/value.

5.Press the START (enter) keypad when the desired status/value appears in the display. The next Agitate step option will appear in the display.

NOTE: To program “drAn” (Drain Step), continue to next Cycle Segment option. To program other options, press the #3 (>) or the #6 (<) keypad and refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to Start Mode.

28

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208801

Page 30
Image 30
Alliance Laundry Systems PHM1263R manual Supply, Agitate Description Status/Value Step