Programming Drain Step

1.When “drAn” appears in the display, press the START (enter) keypad. The current status will be displayed.

2.Press the #3 (>) or the #6 (<) keypad to change the current status.

on” = Drain step is enabled “oFF” = Drain step is disabled

NOTE: Drain must be enabled to activate Extract step.

3.Press the START (enter) keypad when the desired status appears in the display. The next Cycle Segment option, “SPIn”, will appear in the display.

NOTE: To program “SPIn” (Extract Step), continue to next Cycle Segment option. To program other options press the #3 (>) or the #6 (<) keypad and refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to Ready Mode.

Programming Extract Step

1.When “SPIn” appears in the display, press the START (enter) keypad. The first Extract step programming option will appear in the display.

2.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable Extract step options. Refer to Table 9.

NOTE: Extract Step “SPEn” must be enabled to scroll through all Extract step options.

3.Press the START (enter) keypad when the desired option appears in the display. The current status/value will appear in the display. Refer to Table 9.

 

 

 

Programming Control

M

 

 

 

 

Extract

Description

Status/Value

 

 

Step

 

 

 

 

“SPEn”

Extract Step

“on”/“oFF”

 

 

 

Enable/

 

 

 

 

Disable

 

 

 

 

 

 

 

 

“SSEC”

Extract

0-59

 

 

 

Seconds

 

 

 

 

 

 

 

 

“SnIn”

Extract

Intermediate Extract:

 

 

 

Minutes

Minimum

 

 

 

 

Step Time = 30 seconds

 

 

 

 

Maximum

 

 

 

 

Step Time = 3:59 minutes

 

 

 

 

Final Extract:

 

 

 

 

Minimum

 

 

 

 

Step Time = 30 seconds

 

 

 

 

Maximum

 

 

 

 

Step Time = 9:59 minutes

 

 

 

 

 

 

 

“SSPd”

Extract Speed

1 = very low speed (60g)

 

 

 

(VFD only)

2 = low speed

 

 

 

 

(L-speed = 100g;

 

 

 

 

M-speed = 120g)

 

 

 

 

3 = medium speed

 

 

 

 

(L-speed = 100g;

 

 

 

 

M-speed = 180g)

 

 

 

 

 

 

Table 9

4.Press the #3 (>) or the #6 (<) keypad to change the current status/value.

5.Press the START (enter) keypad when the desired status/value appears in the display.

NOTE: To program “Cnin” (Cycle Time Display), continue to next Cycle Segment option. To program other options press the #3 (>) or the #6 (<) keypad and refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to Start Mode.