LK1- Port 1 Activity

On: Fiber link present.

Blinking quickly: Fiber link present and receiving data.

Blinking slowly: The fiber link has been taken down as a result of Smart Link Pass-Through.

Blinking one second on, 3 seconds off: the maximum specified operating temperature within the inserted module has been exceeded.

Off: No fiber link present.

LK2 – Port 2 Activity

On: Copper link present.

Blinking quickly: Copper link present and receiving data.

Blinking slowly: The copper link has been taken down as a result of Smart Link Pass-Through.

Blinking one second on, 3 seconds off: the maximum specified operating temperature within the inserted module has been exceeded.

Off: No copper link present.

LK1 LK2 Error Codes

LK1

LK2

Meaning

 

 

 

Off

Off

Incompatible SFP+ or XFP

 

 

 

Off

On

Power Budget exceeded – XFP’s requesting more power than

 

 

specified port rating.

 

 

 

On

Off

SFP+ or XFP communication error – C/CM-10GT unable to

 

 

communicate with module

 

 

 

On

On

Internal Error

 

 

 