AUTO-Config Jumper (CM models only)

The Auto-Config jumper is located on the outer edge, at the midpoint of the module. Jumper the top and middle pin to select Auto mode. Jumper the middle and bottom pin to select SW mode.

AUTO: When set to Auto the module will, at power-up, check its internal flash memory to see if configuration information has been downloaded to it from a management module. If so it will use this configuration as its running configuration. If there is no configuration in flash it will read the settings of the DIP switches and use those as its running configuration.

SW: When set to SW (Switch), the module will, at power-up, read the settings of the DIP Switches and use those as its running configuration. It will ignore any configuration information in its flash memory.

NOTE: The default jumper setting is AUTO

Perle C/CM-10GT Media Modules Installation Guide

10

Page 10
Image 10
Perle Systems CM-10GT-XFPH, C-10GT-XFPH, CM-10GT-SFP, C-10GT-SFP manual AUTO-Config Jumper CM models only