Fiber Fault Alert Sample Config

Media Converter Module A Configuration

Link Mode–Standard Mode

Fiber Fault Alert

Media Converter Module B Configuration

Link Mode–Smart Link Pass through Mode

Fiber Fault Alert

Sequence of Events

1.Media Converter Module A loses fiber connection (RX).

2.Media Converter Module A notifies the remote Media Converter Module that there is a fault on the Link.

3.Media Converter Module B detects loss of fiber link on receiver (RX).

4.Media Converter Module B turns off transmitter (TX).

Port Selection (Switch 3 – Test Mode)

Switch Position

Port

 

 

Up (default)

1

 

 

Down

2

 

 

When Loopback mode is selected (Switch 1 and Switch 2 down), this switch specifies which port to enable loopback mode on.

Perle C/CM-10GT Media Modules Installation Guide

8

Page 8
Image 8
Perle Systems C-10GT-XFPH manual Fiber Fault Alert Sample Config, Port Selection Switch 3 Test Mode, Switch Position Port