CABLE/DELTA FACTORY SERVICE CENTER. All repairs made by these agencies are fully guaranteed against defective material and workmanship. We cannot guarantee repairs made or attempted by anyone other than these agencies.
Should you have any questions about your tool, feel free to write us at any time. In any communications, please give your tool model and serial number.
TROUBLESHOOTING
WARNING: Disconnect tool from air supply before performing any Service Procedure.
SYMPTOM | PROBLEMS | SOLUTIONS |
1.Air leak near top of tool.
Loose screws. | Tighten cap screws |
Worn or damaged | Install Overhaul Kit. |
|
2. Tool Leaks air or will | Internal valve has | If the tool is dropped after the air |
not function | shifted. | pressure is removed from the tool, |
|
| the internal valve mechanism may |
|
| shift into the open position. When |
|
| connected to the compressed air |
|
| source, the tool will not operate due |
|
| to an air leak. To reset the internal |
|
| valve to the closed position, |
|
| disconnect the air supply and |
|
| sharply impact the tool cap against a |
|
| piece of wood. Connect the air |
|
| supply hose: The air pressure will |
|
| seat the valve in the close position. |
3.Tool does nothing or operates sluggishly.
Inadequate air supply. | Verify adequate air supply. |
Inadequate lubrication. | Put 5 or 6 drops of oil into air inlet. |
Worn or damaged | Install Overhaul Kit. |
|
4.Air leak near bottom of tool.
Loose screws. | Tighten cap screws |
Worn or damaged | Install Overhaul Kit. |
|
5. Other. | Contact a |
| Service Facility. |
ACCESSORIES
A complete line of accessories is available from your
WARNING: Since accessories other than those offered by Porter- Cable • Delta have not been tested with this product, use of such accessories could be hazardous. For safest operation, only Porter- Cable • Delta recommended accessories should be used with this product.
11