Bryant Explore AHRI Ratings and Energy Efficiency for Model 116B

Page 12

116B

TESTED AHRI COMBINATION RATINGS*

NOTE: Ratings contained in this document are subject to change at any time.

For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org

Additional ratings and system combinations can be accessed via the Bryant database at:

http://cactaxcredits.info/bryant-ratings/hp_ratings_srch.php

Equipment performance calculator can be accessed at: http://rpmobbry.wrightsoft.com/

Model Number

Indoor Coil Model Number

Furnace Model Number

Cooling Capacity

EER

SEER

116BNA018****B

CNPV*1917A**

 

18,000

12.0

14.5

116BNA024****A

CNPV*3117A**

 

23,600

12.0

14.5

116BNA030****A

CNPV*3117A**

 

28,600

12.0

14.5

116BNA036****A

CNPV*3717A**

 

34,400

12.0

14.5

116BNA042****A

CNPV*4324A**

 

41,500

12.0

14.5

116BNA048****B

CAP**6025A**

 

46,000

12.0

14.5

116BNA049****A

CAP**6025A**

 

48,000

11.5

14.0

116BNA060****A

CNPV*6124A**

 

56,000

12.0

14.5

116BNA061****A

CNPV*6124A**

 

59,500

12.0

14.5

*AHRI = Air Conditioning, Heating & Refrigeration Institute EER — Energy Efficiency Ratio

SEER — Seasonal Energy Efficiency Ratio

NOTES:

1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.

2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures.

3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.

4. Do not apply with capillary tube coils as performance and reliability are affected.

12

Image 12
Contents Industry Leading Features / Benefits Product DataStandard Features Model Number NomenclaturePhysical Data Refrigerant Piping Length Limitations Vertical Separation ft mLong Line Applications Vapor Line Sizing and Cooling Capacity LossCharging Formula Accessory Thermostats AccessoriesPart Number Program GAS Electric Heat Cool KIT Number DescriptionAccessory Usage Guideline Time-Delay Relay Sound HoodSupport Feet Thermostatic Expansion Valve TXVElectrical Data Charging Subcooling TXV-TYPE Expansion DeviceMAX MIN LRA RLA FLA AmpsDimensions English Dimensions SI Wall 609.6 Service 457.2 ClearancesTested Ahri Combination Ratings Http//cactaxcredits.info/bryant-ratings/hpratingssrch.php105 115 125 Capacity MBtuh† Total System Sens‡525 600875 10001125 10501225 14001575 16001750 20002250 Outdoor Section With CNPV*6124A**+TDR Indoor Section SST Condenser Entering AIR Temperatures F C Condenser only Ratings116BNA036****A 116BNA049****A Guide Specifications General ProductsSystem Design Summary Catalog No PDS116B---04