Grizzly H8145 owner manual Calibrating Blade Tilt Pointer, Table Saw Operations

Page 25

Table Saw Operations

Symptom

 

 

 

Possible Cause

Possible Solution

Workpiece

hits

the

1.

Riving knife is not aligned with the blade.

1.

Realign the riving knife to the blade (Page 24).

riving

knife

 

during

 

 

 

 

cutting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Saw does

not

cut

1.

Pointer on the tilt scale is out of adjust-

1.

Recalibrate the tilt scale pointer (see below).

beveled or 90° cuts

 

ment.

 

 

at an accurate angle;

 

 

 

 

angle of cut does not

 

 

 

 

match tilt scale.

 

 

 

 

 

 

 

 

 

 

 

 

Blade

guard

sticks,

1.

The mounting bolts are too tight.

1.

Readjust the mounting bolts (Page 24).

preventing

it

 

from

 

 

 

 

automatically

drop-

 

 

 

 

ping down

after a

 

 

 

 

cut.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Board

binds

or

1.

Dull blade.

1.

Replace blade.

burns when feeding

2.

Blade is warped.

2.

Replace blade.

through tablesaw.

3.

Fence is not parallel to blade.

3.

Adjust the fence parallel to the blade.

 

 

 

 

 

 

 

 

 

 

4.

Front and rear scales are not aligned paral-

4. Remove the scale on one side and install a new one,

 

 

 

 

 

 

lel to the blade.

 

using a straightedge placed across the blade to align

 

 

 

 

 

 

 

 

the new scale with the old scale and the blade.

 

 

 

 

 

 

 

 

 

Calibrating Blade Tilt

Pointer

The blade tilt pointer is fastened to the table saw body with the hex nut shown in Figure 23. A 6mm wrench is required to loosen the hex nut to adjust the pointer.

Tools Needed

Qty

Wrench 6mm

1

90° Square

1

Pointer Hex

Nut

Figure 23. Pointer hex nut.

To calibrate the blade tilt indicator:

1.DISCONNECT SAW FROM POWER!

2.Loosen the hex nut on the back of the pointer (Figure 23).

3.Using a 90° square as a gauge, adjust the blade so it is square to the table, then tighten the blade tilt handles.

4.Double check that the blade tilt did not change when you tightened the tilt lock handles.

—If the blade tilt did not change, continue to Step 5.

—If the blade tilt did change, repeat Steps 3 & 4.

5.Rotate the blade tilt indicator directly over the "0" mark on the tilt scale.

6.Tighten the hex nut on the back of the pointer, making sure that the indicator does not move during tightening.

H8145 Baby Table Saw

-23-

Image 25
Contents Model H8145 Baby Table SAW Page Table of Contents Foreword IntroductionContact Info Machine Data Sheet Identification Safety Instructions for Machinery H8145 Baby Table Saw Safety Instructions for Table Saws Protecting Yourself From Kickback Preventing KickbackBelow are tips to avoid the most common causes of kickback Glossary of Terms 110V Operation Circuit RequirementsSet Up Safety SET UPUnpacking Items Needed for SetTest Run Dust CollectionTo test run the machine Operations Operation Safety Basic ControlsCombination blade features Ripping blade featuresCrosscut blade features Laminate blade featuresTo setup the fence for standard cutting Fence SetupTo setup the fence for miter cutting Standard CuttingNon-Through Through Cuts Workpiece InspectionNon-Through Cuts Through CutsTypical ripping operation RippingTo make a crosscut Crosscutting 45˚ Miter CutsTo perform a miter cut Changing Blade Blade Tilt/Bevel CutsTo tilt the blade Tools Needed QtyH1234-Table Saw Bench Guide AccessoriesH1300 H1298 G7984 H2347 H0736 G3445-Precision Saw ToolCleaning MaintenanceSchedule DailyTroubleshooting ServiceMotor & Electrical Calibrating Blade Tilt Pointer To calibrate the blade tilt indicatorTable Saw Operations To adjust the blade guard Blade Guard AdjustmentRiving Knife Alignment To align the riving knife with the bladeElectrical Components Wiring Diagram Parts Breakdown Description Parts ListSafety Label Parts Breakdown Warranty and Returns Page Page