Grizzly G0511 instruction manual Circuit Requirements, Model G0506/G0507

Page 8

SECTION 3: CIRCUIT REQUIREMENTS

Model G0506/G0507

The Model G0506/G0507 Bandsaw is pre-wired for single-phase, 220V operation. Under normal use, the Model G0506 2 HP motor draws approx- imately 12 amps. We recommend a 15 amp cir- cuit. This includes a 15 amp circuit breaker, plug, receptacle and wiring rated for at least 15 amps. Under normal use, the Model G0507 3 HP motor draws approximately 22 amps. We recommend a 25 amp circuit. This includes a 25 amp circuit breaker, plug and wiring rated for at least 25 amps. These circuits should be satisfactory for normal use, while providing enough protection against damage caused by an overloaded circuit. If frequent circuit failures occur when using the bandsaw, contact our service department or your local electrical contractor.

This bandsaw must be connected to its own ded- icated circuit; it should not share a circuit with any other machine. A standard 2-pole breaker is nec- essary for use with the Model G0506/G0507.

This bandsaw is not supplied with a cord and power plug. We recommend using a NEMA-style L6-25 plug and outlet similar to Figure 1. You may also “hard-wire” the bandsaw directly to your panel, provided you place a disconnect switch near the machine. Check the electrical codes in your area for specifics on wiring requirements.

Please refer to the wiring diagram on page 30 for power hook-up information.

Figure 1. Typical 220V 3-prong plug and outlet.

Be sure that your particular electrical config- uration complies with local and state codes. The best way to ensure compliance is to check with your local municipality or a licensed electrician.

-6-

18" & 20" Super Heavy-Duty Bandsaws

Image 8
Contents Super HEAVY-DUTY Bandsaws Page Table Of Contents Safety Safety Instructions For Power ToolsLength AMP Rating Additional Safety Instructions For Bandsaws Introduction CommentaryCircuit Requirements Model G0506/G0507Typical plug configuration for Three-phase operation Model G0511 440V OperationGrounding Extension Cords Controls Components IdentificationSET UP Unpacking Piece InventoryHardware Chart InsideClean Up Site ConsiderationsFence To mount the fenceDust Port Guide Post To install the dust portTo adjust the guide post To adjust the blade guides Blade GuardBlade Guides To move the blade guardBlade Tracking Gullet Line To adjust blade trackingTo adjust blade guides to the gullet line Support Bearings To adjust the lateral placementTo adjust the backing placement To tilt the table To adjust the guide bearingsGuide Bearings Table Tilt To adjust the positive stop Table StopFoot Brake Test Run Foot brake is located below Dust collection portTo adjust the tension Blade TensionFence Adjustment Blade Lead To adjust the fence so it is parallel with the bladeOperations Blade SelectionsBlade Length Blade WidthBlade Breakage Tooth PitchBlade Care Loosen this bolt to remove assembly Blade ChangesTo complete a stacked cut Ripping Stacked CutsTo perform ripping operations To resaw lumber, follow the procedure below ResawingMaintenance To adjust the V-beltBelts MiscellaneousLubrication Wheel BrushTo oil the guide bearings As for other items on this machineG0506 &G0507 Wiring Diagram G0511 Wiring Diagram Closure Machine Data Sheet G0506 G0506 G0506 G0506 G0506 Frame Trunnion Bracket Super HEAVY-DUTY Bandsaws G0507/G0511 G0507/G0511 G0507/G0511 G0507/G0511 G0507/G0511 PH 3 HP Motor Flat Washer 5⁄8 Troubleshooting Warranty and Returns Warranty Card Grizzly INDUSTRIAL, INC BOX BELLINGHAM, WAPage Free Gift Call Today For a Free Full Color Catalog