Bard WH602, WH483, WH421 installation instructions Getting Other Information and Publications

Page 3

Getting Other Information and Publications

These publications can help you install the air conditioner or heat pump. You can usually find these at your local library or purchase them directly from the publisher. Be sure to consult current edition of each standard.

National Electrical Code

ANSI/NFPA 70

Standard for the Installation

ANSI/NFPA 90A

of Air Conditioning and

 

Ventilating Systems

 

Standard for Warm Air

ANSI/NFPA 90B

Heating and Air

 

Conditioning Systems

 

Load Calculation for

ACCA Manual J or

Residential Winter and

Manual N

Summer Air Conditioning

 

Low Pressure, Low Velocity

ACCA Manual D or

Duct System Design for Winter

Manual Q

and Summer Air Conditioning

 

FOR MORE INFORMATION, CONTACT THESE PUBLISHERS:

ACCA Air Conditioning Contractors of America

1712 New Hampshire Ave. N.W.

Washington, DC 20009

Telephone: (202) 483-9370

Fax: (202) 234-4721

ANSI

American National Standards Institute

 

11 West Street, 13th Floor

 

New York, NY 10036

 

Telephone: (212) 642-4900

 

Fax: (212) 302-1286

ASHRAE American Society of Heating Refrigerating

and Air Conditioning Engineers, Inc.

1791 Tullie Circle, N.E.

Atlanta, GA 30329-2305

Telephone: (404) 636-8400

Fax: (404) 321-5478

NFPA

National Fire Protection Association

 

Batterymarch Park

 

P.O. Box 9101

 

Quincy, MA 02269-9901

 

Telephone: (800) 344-3555

 

Fax: (617) 984-7057

Manufactured under the following U.S. patent numbers:

5,301,744; 5,002,116; 4,924,934; 4,875,520; 4,825,936; 4,432,409

Other patents pending.

Manual 2100-399

Page 1

Image 3
Contents Models Installation Instructions Wall Mounted Package Heat PumpsContents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsWall Mount General Information Heat Pump Wall Mount Model NomenclatureElectric Heat Table Unit Dimensions Single Circuit Dual Circuit Electrical SpecificationsFilters Shipping DamageGeneral Duct WorkBlower Damper Assembly Fresh AIR IntakeCondensate Drain Mounting the Unit Installation InstructionsTypical Installations Wall Mounting InformationElectric Heat Clearance Mounting InstructionsWALL-MOUNTING Instructions Common WALL-MOUNTING Installations Wiring Main Power Wiring LOW Voltage WiringUnit 24V Terminal Board Heat Anticipation Thermostat WiringThermostat Wire Size Compressor Cutoff and Outdoor Thermostat WiringCompressor Malfunction Light Thermostat Indicator LampsThermostat Subbase Predominant Features Emergency Heat PositionStart UP Important Installer NoteHigh Pressure Switch Three Phase Scroll Compressor Start UP InformationSequence of Operation Phase MonitorService Hints Pressure Service PortsDefrost Control Board Troubleshooting Solid State Heat Pump Control Troubleshooting ProcedureTroubleshooting Temperature F VS. Resistance R of Temperature Sensor Checking Temperature Sensor Outside Unit CircuitFAN Blade Setting Dimensions Removal of FAN ShroudRefrigerant Charge Return Air Model Cooling Pressure ALL Temperatures FMaximum ESP of Operation Electric Heat only Model WH421 WH483 WH602 Speed KW High Speed Low SpeedHeating Pressures ALL Temperatures F Optional AccessoriesPressure
Related manuals
Manual 29 pages 26.38 Kb Manual 8 pages 45.17 Kb

WH421, WH483, WH602 specifications

Bard WH602, WH421, and WH482 are distinguished models in Bard's line of high-performance wall-mounted heaters. Each unit is designed to offer reliable heating solutions for various commercial and industrial applications. These models are renowned for their energy efficiency, robust construction, and ease of use, making them ideal for a variety of environments, including warehouses, manufacturing facilities, and other large spaces.

The WH602 model boasts impressive heating capabilities, featuring a powerful fan-forced heater equipped with a 60000 BTU rating. This allows it to effectively heat large areas quickly and efficiently. One of its main features is the high-efficiency, stainless steel heat exchanger that promotes better heat transfer, enhancing the overall performance and longevity of the heater. The WH602 is designed with energy-saving technology, allowing it to operate with minimal electricity consumption while maximizing output.

The WH421 model offers a more compact solution without sacrificing power. With a heating capacity of 42000 BTU, it is suitable for medium-sized spaces. Like the WH602, the WH421 utilizes a stainless steel heat exchanger, ensuring durability and efficient heating. This model is equipped with a quiet, high-performance fan that distributes heat uniformly throughout the space, maintaining comfortable conditions without the distraction of excessive noise. Its compact design also allows for easy installation in tighter spaces.

The WH482 is a versatile model that falls between the two in terms of performance and application. Rated at 48000 BTU, it combines the benefits of both the WH602 and WH421, making it suitable for various heating demands. The WH482 features advanced control options, allowing users to set specific heating schedules and temperatures for improved comfort and energy efficiency. Additionally, it has built-in safety features like over-temperature protection and a thermal cutoff switch, ensuring safe operation in commercial environments.

All three models share key characteristics, including a robust construction built to withstand harsh conditions, user-friendly controls, and compliance with industry safety standards. Their wall-mounted design saves valuable floor space while providing powerful heating performance. Overall, Bard WH602, WH421, and WH482 represent a commitment to quality, performance, and customer satisfaction, making them top choices for businesses seeking efficient heating solutions.