WALL MOUNT GENERAL INFORMATION

HEAT PUMP WALL MOUNT MODEL NOMENCLATURE

MODEL NUMBER

WH

CAPACITY

 

42

3-1/2 Ton

REVISION

48

– 4 Ton

60

– 5 Ton

 

 

 

 

 

CONTROL MODULES

48 1A 10 X X X X X B

(See Chart Below)

 

 

 

COIL OPTIONS

 

 

X – Standard

VENTILATION OPTIONS

1

– Phenolic Coated Evaporator

2

– Phenolic Coated Condenser

VOLTS & PHASE A – 230/208/60-1 B – 230/208/60-3 C – 460/60-3

KW

00 – No KW

05 – 5 KW

06 – 6KW

09 – 9 KW

10 – 10 KW

15 – 15 KW

18 – 18 KW

20 – 20 KW

X – Barometric Fresh Air Damper

 

 

3 – Phenolic Coated Evaporator

 

(Standard)

 

COLOR OPTIONS

and Condenser

B –

Blank-off Plate

 

 

M – Motorized Fresh Air Damper

X – Beige (Standard)

V – Commercial Room Ventilator

1

– White

 

 

- Motorized with Exhaust

 

2

– Mesa Tan

 

E –

Economizer (Internal) - Fully

3

– Colonial White

OUTLET OPTIONS

 

Modulating with Exhaust

 

4

– Buckeye Gray

 

 

X – Front (Standard)

R – Energy Recovery Ventilator -

 

 

 

 

 

 

Motorized with Exhaust

FILTER OPTIONS

 

X– One Inch Throwaway (Standard)

W– One Inch Washable P – Two Inch Pleated

NOTE: For 0KW and circuit breakers (230/208 V) or pull disconnects (460 V) applications, insert 0Z in the KW field of model number.

TABLE 1

ELECTRIC HEAT TABLE

Models

 

WH421-A

 

 

WH421-B

 

WH421-C

 

WH483-A

 

 

WH483-B

 

WH483-C

 

 

 

 

WH483-B

 

 

WH602-A

 

 

WH602-B

 

WH602-C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240-1

208-1

240-3

208-3

460-3

240-1

208-1

240-3

208-3

460-3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

A

BTU

A

BTU

A

BTU

A

BTU

A

BTU

A

BTU

A

BTU

A

BTU

A

BTU

A

BTU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

16.7

13650

14.4

10240

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

20.8

17065

18.1

12800

 

 

 

 

 

 

20.8

17065

18.1

12800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

14.4

20500

12.5

15360

7.2

20480

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

21.7

30600

18.7

23030

10.8

30700

 

 

 

 

21.7

30600

18.7

23030

10.8

30700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

41.6

34130

36.2

25600

 

 

 

 

 

 

41.6

34130

36.2

25600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

62.5

51200

54.1

38400

36.2

51200

31.2

38400

18.0

51200

62.5

51200

54.1

38400

36.2

51200

31.2

38400

18.0

51200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43.3

61400

37.5

46050

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

83.2

68250

72.1

51200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual 2100-399 Page 2

Image 4
Contents Installation Instructions Wall Mounted Package Heat Pumps ModelsContents Getting Other Information and Publications For More INFORMATION, Contact These PublishersHeat Pump Wall Mount Model Nomenclature Wall Mount General InformationElectric Heat Table Unit Dimensions Electrical Specifications Single Circuit Dual CircuitShipping Damage GeneralDuct Work FiltersFresh AIR Intake Blower Damper AssemblyCondensate Drain Installation Instructions Typical InstallationsWall Mounting Information Mounting the UnitMounting Instructions Electric Heat ClearanceWALL-MOUNTING Instructions Common WALL-MOUNTING Installations Wiring LOW Voltage Wiring Wiring Main PowerUnit 24V Terminal Board Thermostat Wiring Thermostat Wire SizeCompressor Cutoff and Outdoor Thermostat Wiring Heat AnticipationThermostat Indicator Lamps Thermostat Subbase Predominant FeaturesEmergency Heat Position Compressor Malfunction LightImportant Installer Note High Pressure SwitchThree Phase Scroll Compressor Start UP Information Start UPPhase Monitor Service HintsPressure Service Ports Sequence of OperationDefrost Control Board Solid State Heat Pump Control Troubleshooting Procedure TroubleshootingTroubleshooting Checking Temperature Sensor Outside Unit Circuit Temperature F VS. Resistance R of Temperature SensorRemoval of FAN Shroud FAN Blade Setting DimensionsRefrigerant Charge Cooling Pressure ALL Temperatures F Maximum ESP of Operation Electric Heat onlyModel WH421 WH483 WH602 Speed KW High Speed Low Speed Return Air ModelOptional Accessories Heating Pressures ALL Temperatures FPressure
Related manuals
Manual 29 pages 26.38 Kb Manual 8 pages 45.17 Kb

WH421, WH483, WH602 specifications

Bard WH602, WH421, and WH482 are distinguished models in Bard's line of high-performance wall-mounted heaters. Each unit is designed to offer reliable heating solutions for various commercial and industrial applications. These models are renowned for their energy efficiency, robust construction, and ease of use, making them ideal for a variety of environments, including warehouses, manufacturing facilities, and other large spaces.

The WH602 model boasts impressive heating capabilities, featuring a powerful fan-forced heater equipped with a 60000 BTU rating. This allows it to effectively heat large areas quickly and efficiently. One of its main features is the high-efficiency, stainless steel heat exchanger that promotes better heat transfer, enhancing the overall performance and longevity of the heater. The WH602 is designed with energy-saving technology, allowing it to operate with minimal electricity consumption while maximizing output.

The WH421 model offers a more compact solution without sacrificing power. With a heating capacity of 42000 BTU, it is suitable for medium-sized spaces. Like the WH602, the WH421 utilizes a stainless steel heat exchanger, ensuring durability and efficient heating. This model is equipped with a quiet, high-performance fan that distributes heat uniformly throughout the space, maintaining comfortable conditions without the distraction of excessive noise. Its compact design also allows for easy installation in tighter spaces.

The WH482 is a versatile model that falls between the two in terms of performance and application. Rated at 48000 BTU, it combines the benefits of both the WH602 and WH421, making it suitable for various heating demands. The WH482 features advanced control options, allowing users to set specific heating schedules and temperatures for improved comfort and energy efficiency. Additionally, it has built-in safety features like over-temperature protection and a thermal cutoff switch, ensuring safe operation in commercial environments.

All three models share key characteristics, including a robust construction built to withstand harsh conditions, user-friendly controls, and compliance with industry safety standards. Their wall-mounted design saves valuable floor space while providing powerful heating performance. Overall, Bard WH602, WH421, and WH482 represent a commitment to quality, performance, and customer satisfaction, making them top choices for businesses seeking efficient heating solutions.