Global Machinery Company MOC6L Stopping the air Compressor, Assembly Included Accessories

Page 11

To increase the regulated air pressure rotate the pressure regulating knob clockwise. To decrease the regulated air pressure rotate the regulating knob anti-clockwise.

When setting the the regulated outlet pressure always start with the pressure being low, working your way up to the desired regulated pressure.

Note. Ifyou do not allow the air to discharge while you are setting the regulator, the pressure as indicated on the regulated outlet gauge will be incorrect. This gauge ONLY indicates the correct pressure while air is being discharged from the outlet and through the air tool/accessory to be used.

Stopping the air

 

E

compressor

 

On completion of using the

 

compressor, or when you are

 

leaving the compressor unattended,

 

turn off the compressor in the

 

following way:

 

1. Switch the yellow “On/Off”

 

(1) switch to the “off” position

 

F

(Fig. E).

 

2.Switch off the electrical power supply and remove the electrical plug.

3.Set the regulated outlet pressure to zero by turning the pressure regulating knob (9) anti clockwise

and set the regulated outlet

G

pressure gauge (12) to zero

 

(Fig. F).

 

4.Disconnect the air hose, accessories and air tool from the compressor.

5.Pull the ring on the safety valve (10) to ensure all the pressurised

air is released from the tank (Fig. G), or open the drain cock (13) to release the pressure from the tank.

Note. Always shut off the compressor after use and before servicing.

WARNINGS.

1.Never attempt to remove any part of the compressor whilst the tank is under pressure.

2.Never attempt to remove any electrical component whilst the compressor is connected to the power supply. Switch off the power and remove the electrical plug.

3.Do not adjust the safety valve.

4.Take care when discharging air from the tank, i.e. from the safety valve, the drain cock or the air outlet. Compressed air can be extremely dangerous. Make sure that the discharged air does not cause dust, stones or any other foreign particles to be blown through the air and that the air is discharged in a safe manner.

Assembly - Included Accessories

Your air compressor accessory kit comes with a variety of accessories.

Operating the quick change blow gun

1.The air gun can be connected to the regulated air outlet supply on the compressor.

2. Prior to connecting to the air

H

line, you need to assemble

 

the quick change blow gun.

 

To assemble select one of the

 

supplied 1/4” male Nitto style

 

plugs/adaptors (21). Apply the

 

supplied Teflon tape to the male

 

thread on the 1/4” male Nitto

 

style plug/adaptor (21) (Fig. H).

 

I

Screw the 1/4” male Nitto style

plug/adaptor (21) into the air

 

1/4” female threaded air inlet

 

side of the quick change blow

 

gun (15). Tighten this fitting

 

with a wrench for an air tight

 

seal (Fig. I).

 

 

 

11

Image 11
Contents 6LT Contents From AC mains only Environmental protection Description of symbolsSpecifications IntroductionUse safety equipment. Always wear eye protection General safety rulesPersonal safety Do not use the power tool if the switch does not turn Additional safety rules for air compressorsPower tool use and care Wear goggles Wear earmuffs Wear a breathing mask Components UnpackingKnow your product Operating the air compressor To start the air compressorOperating the quick change blow gun Assembly Included AccessoriesStopping the air Compressor Connecting the inflation needle to the quick change blow gun Main compressor sticking/tight Connecting the tyre inflatorTroubleshooting Slow or becoming excessively hotOutlet capacity Insufficient pressure or decreasedSelect another air tool that that will General inspection MaintenancePower cord maintenance CleaningPage Page GMC customer assist