APPENDIX: 12.4 WIRING DIAGRAMS

12.4.4 Legend

A1

Wire jumper across J5-ID3>X2 must be inserted if no utility company disable contactor is used

A2

Wire jumper, must be removed if 2nd disable input is used

 

A7

Wire jumper in SI 50/-70, in place of F18/F19

 

B2*

Pressostat low pressure, brine

 

B3*

Thermostat, hot water (as an alternative to hot water sensor)

 

B4*

Thermostat, swimming pool water

 

E9*

Electr. immersion heater, hot water

 

E10*

Suppl. heating system (boiler or electr. heating element)

 

F2

Load fuse for N1 relay outputs across J12 and J13

4.0 A slow-acting

F3

Load fuse for N1 relay outputs across J15 to J18

4.0 A slow-acting

F4

Pressostat, high pressure

 

F5

Pressostat, low pressure

 

H5*

Lamp, remote fault indicator

 

J1...J18

Terminal connector at N1

 

K1

Contactor, compressor 1

 

K3

Contactor, compressor 2

 

K11*

Electron. relay for remote fault indicator (relay module)

 

K12*

Electron. relay for swimming pool water circulating pump (relay module)

K20*

Contactor, suppl. heating system (boiler or electr. heating element)

K21*

Contactor, electr. immersion heater for hot water

 

K22*

Utility company disable contactor

 

K23*

SPR auxiliary contactor

 

M1

Compressor 1

 

M3

Compressor 2

 

M11*

Primary pump

 

M13*

Heating circulating pump

 

M15*

Heating circulating pump for heating circuit 2

 

M16*

Suppl. circulating pump

 

M18*

Hot water circulating pump

 

M19*

Swimming pool circulating pump

 

M21*

Mixer, principal circuit

 

M22*

Mixer, heating circuit 2

 

N1

Heat pump controller

 

N7

Starting current limiter, compr. 1

 

N8

Starting current limiter, compr. 2

 

N10*

Remote control station

 

N11*

Relay module

 

R1

External sensor

 

R2

Return sensor

 

R3*

Hot water sensor (as an alternative to hot water thermostat)

 

R5*

Sensor for heating circuit 2

 

R6

Freeze protection sensor

 

R7

Coding resistor 8k

 

R9

Flow sensor

 

T1

Safety isolating transformer 230/24 VAC-28VA

 

X1

Terminal strip mains control L/N/PE-230VAC-50Hz/fuses/N and PE-terminal block

X2

Terminal strip 24 VAC-terminal block

 

X3

Terminal strip GND terminal block for sensors R1/-2 and -3 at J2 and R5 and -6 at J6

X5

Terminal strip power supply 3L/PE-400VAC-50 Hz

 

Abbreviations:

 

 

EVS

Utility company disable input

 

SPR

Supplementary disable input

 

MA

Mixer OPEN

 

MZ

Mixer CLOSED

 

* Components to be supplied by the customer, available as accessories

22

Image 22
Contents Operating Instructions Purpose of Heat Pump Important Information Legal Provisions and Guidelines Read ImmediatelyEnergy-Efficient Use of the Heat Pump Application Purpose of the Heat PumpScope of Delivery Principle of OperationConnecting Flanges AccessoriesTransport General Information InstallationMounting Sound EmissionsConnection on Heat Source Side Electrical ConnectionCommissioning Commissioning ProcedurePreparatory Steps Cleaning of Heat Source Side CARE/CLEANINGCleaning of Heating Side CareSummer Shutdown Malfunctions 11DECOMMISSIONING TroubleshootingCorrection of Minor Malfunctions by Owner End-of-Life Decommissioning/ DisposalWiring Diagrams Dimensioned DrawingsEquipment Data Diagrams AppendixDimensioned Drawing SI 50ZS Dimensioned Drawing SI 75ZS Dimensioned Drawing SI 100ZS Equipment Data Characteristic Curves SI 50ZS EvaporatorCharacteristic Curves SI 75ZS Characteristic Curves SI 100ZS Control Load Terminal Diagram InputEVS Hydraulic Block Diagram Example EC Declaration of Conformity Page Page