12
12 Device Information
English
1Type and order code
2Design
2.1Degree of protection according to EN 60 529
2.2Installation Location
3 Performance data
3.1Operating temperature limits:
Heating water flow | °C |
Brine (heat source) | °C |
Antifreeze |
|
Minimum brine concentration
3.2Temperature spread of heating water (flow/return flow)
|
| at B0 | / W35 | K |
3.3 | Heat output / COP | at | kW / | |
|
| at B0 | / W45 1 | kW / |
|
| at B0 | / W50 1 | kW / |
|
| at B0 | / W35 1 | kW / |
3.4 | Sound power level |
|
| dB(A) |
3.5Heating water flow with an internal pressure differential of m³/h / Pa
3.6Brine throughput with an internal pressure
| differential (heat source) of |
| m³/h / Pa |
3.7 | Refrigerant; total filling weight |
| type / kg |
4 | Dimensions, connections and weight |
| |
4.1 | Device dimensions without connections 2 | H x W x L mm | |
4.2 | Device connections to heating system | Inch | |
4.3 | Device connections to heat source |
| Inch |
4.4 | Weight of the transportable unit(s) incl. packing | kg | |
5 | Electrical Connection |
|
|
5.1 | Nominal voltage; fuse protection |
| V / A |
5.2 | Nominal power consumption 1 | B0 W35 | kW |
5.3 | Starting current with soft starter |
| A |
5.4 | Nominal current B0 W35 / cos ϕ |
| A / |
6Complies with the European safety regulations
7Additional model features
7.1Water in device protected against freezing 4
7.2Performance levels
7.3Controller internal/external
SI 5ME | SI 7ME | SI 9ME | SI 11ME | SI 14ME | ||||||||||||
IP 20 | IP 20 | IP 20 | IP 20 | IP 20 | ||||||||||||
Indoors | Indoors | Indoors | Indoors | Indoors | ||||||||||||
Up to 58 | Up to 58 | Up to 58 | Up to 58 | Up to 58 | ||||||||||||
ene glycol | ene glycol | ene glycol | ene glycol | ene glycol | ||||||||||||
25% | 25% | 25% | 25% | 25% | ||||||||||||
9.6 |
| 9.1 |
| 5.0 | 10.5 |
| 5.0 | 9.5 |
|
| 5.0 | 9.6 |
|
| 5.0 | |
| 5.0 |
|
|
|
|
|
| |||||||||
4.0 / |
|
| 5.4 / |
|
| 7.6 / |
|
| 9.4 / |
|
| 12.3 | / |
|
| |
2.0 |
|
| 2.1 |
|
| 2.1 |
|
| 2.0 |
|
|
| 2.1 |
|
|
|
|
| 4.6 / |
|
| 5.7 / |
|
| 8.5 / |
|
|
| 10.0 / |
|
|
| 14.7 / |
|
| 2.7 |
|
| 2.7 |
|
| 2.8 |
|
|
| 2.9 |
|
|
| 2.9 |
4.8 / |
|
| 6.2 / |
|
| 8.8 / |
|
| 10.5 | / |
|
| 14.2 | / |
|
|
2.7 |
|
| 2.7 |
|
| 2.7 |
|
| 2.6 |
|
|
| 2.8 |
|
|
|
5.0 / |
| 4.9 / | 6.5 / |
| 6.3 / | 9.3 / |
| 8.9 / | 11.0 | / |
| 10.8 / | 15.0 | / |
| 14.8 / |
4.0 |
| 3.8 | 3.9 |
| 3.7 | 4.0 |
| 3.8 | 4.0 |
|
| 3.9 | 4.1 |
|
| 3.9 |
54 | 55 | 56 |
| 56 |
| 56 | ||||||||||
0.45 / |
| 0.6 / |
| 1.1 / | 0.75 / |
| 1.5 / | 1.0 / |
| 1.9 / | 1.3 / |
| 2.6 / | |||
| 0.85 / |
|
|
|
| |||||||||||
1900 |
| 6500 | 3300 |
| 10000 | 2300 |
| 9200 | 4100 |
| 15000 | 4800 |
| 19200 | ||
1.2 / |
| 1.2 / | 1.7 / |
| 1.7 / | 2.3 / |
| 2.0 / | 3.0 / |
| 2.5 / | 3.5 / |
| 3.5 / | ||
16000 | 16000 | 29500 | 29500 | 25000 | 20000 | 24000 | 18000 | 20000 | 20000 | |||||||
R407C / 1.2 | R407C / 1.4 | R407C / 1.7 | R407C / 1.9 | R407C / 2.2 | ||||||||||||
805 ⋅ 650 ⋅ | 805 ⋅ 650 ⋅ | 805 ⋅ 650 ⋅ | 805 ⋅ 650 ⋅ | 805 ⋅ 650 ⋅ | ||||||||||||
462 | 462 | 462 |
| 462 |
| 462 | ||||||||||
G 1¼" exter- | G 1¼" exter- | G 1¼" exter- | G 1¼" exter- | G 1¼" exter- | ||||||||||||
nal | nal | nal |
| nal |
| nal | ||||||||||
G 1¼" exter- | G 1¼" exter- | G 1¼" exter- | G 1¼" exter- | G 1¼" exter- | ||||||||||||
nal | nal | nal |
| nal |
| nal | ||||||||||
109 | 111 | 118 |
| 122 |
| 130 | ||||||||||
230 / 16 | 230 / 16 | 230 / 20 | 230 / 25 | 230 / 32 | ||||||||||||
1.26 |
| 1.68 |
| 1.70 | 2.30 |
| 2.35 | 2.75 |
| 2.77 | 3.70 |
| 3.76 | |||
| 1.30 |
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
24 | 26 | 38 |
| 38 |
| 50 | ||||||||||
6.8 / |
| 9.1 / |
| 9.3 / | 12.6 / |
| 12.9 / | 15.0 | / |
| 15.3 / | 19.7 | / |
| 20.0 / | |
| 7.1 / |
|
|
|
| |||||||||||
0.8 |
| 0.8 | 0.8 |
| 0.8 | 0.8 |
| 0.8 | 0.8 |
|
| 0.8 | 0.8 |
|
| 0.8 |
| 3 |
| 3 |
| 3 |
|
| 3 |
|
| 3 | |||||
No | No | No |
| No |
| No | ||||||||||
| 1 |
| 1 |
| 1 |
|
| 1 |
|
| 1 | |||||
Internal | Internal | Internal | Internal | Internal | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1.This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
2.Note that additional space is required for pipe connections, operation and maintenance.
3.See CE declaration of conformity
4.The heat circulating pump and the heat pump controller must always be ready for operation.