Dimplex SI 14ME, SI 9ME, SI 7ME, SI 5ME, SI 11ME manual Accessories, Transport, Set-up

Page 5

4

English

4 Accessories

4.1Brine Circuit Manifold

The brine circuit manifold merges the individual collector loops of the heat source system into a single main pipe which is con- nected to the heat pump. Integrated ball valves allow the individ- ual brine circuits to be shut off for de-aeration purposes.

5 Transport

A lift truck is suited for transporting the unit on a level surface. Carrying straps may be used if the heat pump needs to be trans- ported on an uneven surface or carried up or down stairs. These straps can be passed directly underneath the wooden pallet.

ATTENTION!

The heat pump is not secured to the wooden pallet.

ATTENTION!

The heat pump must not be tilted more than 45° (in any direction).

Use the holes provided in the sides of the frame to lift the unit without the pallet. The side panel assemblies must be removed for this purpose. Any commercially available length of pipe can be used as a carrying aid.

ATTENTION!

Do not use the holes in the panel assemblies for lifting the device!

6 Set-up

6.1General Information

The unit may only be installed indoors in rooms with low humidity on a level, smooth and horizontal surface. The entire base of the frame should lie directly on the floor to ensure a good soundproof seal. If this is not the case, additional sound insulation measures may be necessary.

The heat pump must be installed so that maintenance work can be carried out without hindrance. This can be ensured by main- taining a clearance of approx. 1 m in front of and on each side of the heat pump.

6.2Acoustic Emissions

The heat pump operates silently due to efficient sound insulation. To prevent noise transmission to the foundation, a suitable, sound dampening rubber mat should be placed underneath the base frame of the heat pump.

To prevent any sound from being transmitted to the heating sys- tem, we recommend connecting the heat pump to the heating system by means of hose sections.

E-4

Image 5
Contents SI 5ME SI 7ME SI 9ME SI 11ME SI 14ME Table of contents Important Information Please Read ImmediatelyLegal Regulations Directives Energy-Efficient Use Heat PumpBasic Device Purpose of the Heat PumpApplication Operating PrincipleSet-up AccessoriesTransport Heating System Connection InstallationHeat Source Connection Electrical ConnectionPreparation Start-up ProcedureCommissioning Decommissioning / Disposal Maintenance and CleaningFaults / Trouble- Shooting Performance data Device InformationIII Anhang / Appendix / AnnexesMaßbild / Dimension Drawing / Schéma coté Maßbilder / Dimension Drawings / Schémas cotés3XLVVDQFHGHFKDXIIDJHHQN@ Diagramme / Diagrams / Diagrammes     Anhang VII Steuerung / Control / Commande Stromlaufpläne / Circuit Diagrams / Schémas électriquesLast / Load / Charge 1HW0DLQV5pVHDX Abréviations Abkürzungen Abbreviations XII Darstellung / Schematic View / ReprésentationXiii XIV