OPERATING INSTRUCTIONS

USING THE TOOL

Complete all steps of PREPARING THE TOOL before using the tool.

This tool is shipped from the factory with a “single sequential actuation” trigger. To fire, grip the tool firmly to maintain control, position nose of tool onto work surface, push the tool firmly against work surface to depress safety (S) Fig. 24, and squeeze trigger to fire a fastener. Allow tool to recoil away from work surface as fastener is driven. This “single sequential actuation” method provides the most accurate fastener placement.

Fig. 24

S

 

Disconnect tool from air supply before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, or handing the tool to another person.

Clean and inspect tool daily. Carefully check for proper operation of trigger and safety mechanism. Do Not use the tool unless both the trigger and the safety mechanism are functional, or if the tool is leaking air or needs any other repair.

9

Image 9
Contents Brad Nailer/Stapler Date of Manufacture Important Safety Instructions Safety Guidelines / DefinitionsGeneral Safety Rules Page Page Power Source EMPLOYER’S ResponsibilitiesFunctional Description Preparing the Tool Operating Instructions Using the ToolRubber Nose Cushion Clearing a Jammed Fastener Maintenance Clean and Inspect DailyService and Repairs Symptom Problems TroubleshootingAccessories Two Year Limited New Product WarrantyCanadian PORTER-CABLE Delta Service Centers