Delta CP200, D27930 instruction manual Before Starting, Before Each Start-Up, How to Stop

Page 12

Motor Overload Protector (not shown): The motor has an automatic reset thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. The compressor will automatically restart after the motor cools.

The motor will automatically restart without warning if plugged in electrical outlet and "Auto/On/Off" switch is in

the "AUTO/ON" position.

How to Use Your Unit

How to Stop:

1.Set the Auto/On/Off switch to "OFF". NOTE: It is normal for the fan to run continuously when the unit is in the "ON" position. To turn the fan off, switch the unit to the "OFF" positon.

Before Starting

Break-in Procedure

Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the Auto/On/Off switch is in the "OFF" position.

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Open the drain valve fully (counterclockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

4.Set the Auto/On/Off switch to "AUTO/ON" position. The compressor will start.

5.Run the compressor for 5 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 5 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up:

1.Set Auto/On/Off switch to "OFF".

2.Turn regulator knob counterclockwise until it stops.

3.Attach hose and accessories.

Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure

rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

D27930

12- ENG

Image 12
Contents Oil-Free Air Compressor Safety Guidelines Definitions Important Safety InstructionsSerious injury Result in property damage Hazard Attachments & Accessories Hazard What can Happen HOW to Prevent IT Hazard Specifications GlossaryModel No CP200 Installation Location of the Air CompressorVolt U.S.A. Plug Extension Cords Voltage and Circuit ProtectionAuto/On/Off Switch Set switch Pressure Switch not shownOperation Know Your Air Compressor Description of OperationHow to Stop Before StartingBefore Each Start-Up Maintenance How to StartTo Check Safety Valve Customer ResponsibilitiesStorage Troubleshooting Problem Cause Correction AIR Compressor Repair Parts Limited Warranty