Delta D27930, CP200 Maintenance, How to Start, Customer Responsibilities, To Check Safety Valve

Page 13

How to Start:

1.Set the Auto/On/Off switch to "AUTO/ON" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.Turn regulator knob clockwise until desired pressure is reached.

The compressor is ready for use.

NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area.

 

MAINTENANCE

Customer Responsibilities

 

 

 

 

 

Before each use

Daily or after

 

each use

 

 

Check Safety Valve

 

 

 

 

Drain Tank

 

To Check Safety Valve

If the safety valve does not work properly, over- pressurization may occur, causing air tank

rupture or an explosion. Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.

To Drain Tank

1.Set the Auto/On/Off switch to "OFF".

2.Turn regulator knob counterclockwise to set the outlet pressure to zero.

3.Remove the air tool or accessory.

4.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

5.Drain water from air tank by opening drain valve (counter-clockwise) on bottom of tank. NOTE: Tilt tank forward to drain tank completely.

Water will condense in the air tank. If not drained, water will corrode and weaken the air tank

causing a risk of air tank rupture.

6.After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.

13- ENG

D27930

Image 13
Contents Oil-Free Air Compressor Important Safety Instructions Safety Guidelines DefinitionsSerious injury Result in property damage Hazard Attachments & Accessories Hazard What can Happen HOW to Prevent IT Hazard Glossary SpecificationsModel No CP200 Location of the Air Compressor InstallationVolt U.S.A. Plug Voltage and Circuit Protection Extension CordsPressure Switch not shown Auto/On/Off Switch Set switchOperation Know Your Air Compressor Description of OperationBefore Starting How to StopBefore Each Start-Up How to Start MaintenanceTo Check Safety Valve Customer ResponsibilitiesStorage Troubleshooting Problem Cause Correction AIR Compressor Repair Parts Limited Warranty