TROUBLESHOOTING

Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or

compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure.

PROBLEM

CAUSE

CORRECTION

Fan continues

It is normal for the fan to run

to run when

continuously when the unit

Auto/On/Off

is in the "ON" position.

switch is in the

 

"ON" position.

 

To stop fan, Turn the Auto/On/Off switch to the "OFF" position.

 

Thermal

Low voltage

Extension cord is wrong

 

overload

 

length or gauge. Check

 

protector cuts

 

extension cord.

 

out repeatedly

Improper ventilation/

Operate compressor in a

 

 

temperature too high

well ventilated area.

 

 

Defective check valve

Contact a Trained Service

 

 

 

Technician

 

 

Defective valves

Contact a Trained Service

 

 

 

Technician

 

 

 

 

 

Excessive tank

Compressor does not turn

Set Auto/On/Off switch to

 

pressure - safety

off when compressor

the "OFF" position, if the

 

valve pops off.

reaches "cut-out" pressure.

unit does not shut off contact

 

 

 

a Trained Service Technician.

 

 

 

Contact a Trained Service

 

 

Pressure switch "cut-out"

Technician.

 

 

too high.

 

 

 

 

 

 

 

 

 

 

 

 

Air leaks at

Tube fittings are not tight

Using a soapy water solution

 

check all exposed fittings for

 

fittings.

enough.

 

leaks. If needed reseal

 

 

 

 

 

 

fittings with pipe sealant

 

 

 

tape and retighten securely.

 

 

 

Do Not Overtighten. If

 

 

 

leaks continue contact a

 

 

 

Trained Service Technician.

 

 

 

 

 

 

 

 

 

Air leaks in air

Defective air tank.

Air tank must be replaced.

tank or at air

 

Do not repair the leak.

tank welds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not drill into, weld or

 

 

 

otherwise modify air tank

 

 

 

or it will weaken. The tank

 

 

 

can rupture or explode.

15- ENG

D27930

Image 15
Contents Oil-Free Air Compressor Safety Guidelines Definitions Important Safety InstructionsSerious injury Result in property damage Hazard Attachments & Accessories Hazard What can Happen HOW to Prevent IT Hazard Specifications GlossaryModel No CP200 Installation Location of the Air CompressorVolt U.S.A. Plug Voltage and Circuit Protection Extension CordsKnow Your Air Compressor Description of Operation Auto/On/Off Switch Set switchPressure Switch not shown OperationHow to Stop Before StartingBefore Each Start-Up Customer Responsibilities MaintenanceHow to Start To Check Safety ValveStorage Troubleshooting Problem Cause Correction AIR Compressor Repair Parts Limited Warranty