INSTALLATION

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

GROUNDING INSTRUCTIONS

RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing

an escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see illustrations). The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances.

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration as the grounded plug. DO NOT

USE AN ADAPTER.

Grounding

Pin

120 Volt U.S.A. Plug

Grounding

Pin

When used outside of the United 240 Volt U.S.A. Plug States of America a conversion kit may be required for

local use.

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.

IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified electrician.

9- ENG

D27930

Image 9
Contents Oil-Free Air Compressor Safety Guidelines Definitions Important Safety InstructionsSerious injury Result in property damage Hazard Attachments & Accessories Hazard What can Happen HOW to Prevent IT Hazard Specifications GlossaryModel No CP200 Installation Location of the Air CompressorVolt U.S.A. Plug Voltage and Circuit Protection Extension CordsPressure Switch not shown Auto/On/Off Switch Set switchOperation Know Your Air Compressor Description of OperationHow to Stop Before StartingBefore Each Start-Up How to Start MaintenanceTo Check Safety Valve Customer ResponsibilitiesStorage Troubleshooting Problem Cause Correction AIR Compressor Repair Parts Limited Warranty