Emerson 20/20 service manual Bottom Status Bar

Page 35

Section 4 • Main Screen

Bottom Status Bar

The bottom status bar gives the operator easy access to some basic functions and information. The functions are available via the four button, see Figure 4-5. Bottom Status Bar.

Maintenance Button:

Pressing the maintenance button will give the op- erator access to the maintenance charts and sign off tables.

User Access Button:

• This button takes the operator to another login

screen to create additional users. Log off Button:

Pressing the log off button logs off the correct user if any are logged in.

Help Button:

Pressing the help button takes the operator to the help screen where the operator can access an opera- tion and service manual and also get access to pro- gram information.

Status Bars

The information available is provide by two status bars, one for maintenance activities and the other for any alarms or trips that might be active. To the right of the status bars are positions for displaying the cur- rent user (if any are logged in), the date and time, and the total run hours of the compressor.

Figure 4-5. Bottom Status Bar

Vission 20/20 • Operation and Service Manual •Vilter/Emerson • 35391SC 1.8.5153

4 – 5

Image 35
Contents Vission 20/20 micro-controller Page Table of Contents Digital I/O Board Layout Top Status Bar TOCCompressor Sequencing Event List Data Backup List of Tables and Figures END of TOC How to Use This Manual Compressor Amperage Load Limiting Operational Flow ChartsRequirements to Start Compressor Critical Compressor Run Logic at Compressor StartOperational Flow Charts 2 Voltage Source Installation RecommendationsProper Wiring Sizing Mixing Voltages DC signalsGrounding Correct Transformer Wiring Method Wiring MethodsBest Practices Overview Hardware ArchitectureDigital Input/Output I/O Board Description Type Digital I/O 1Refer to -2. Analog Inputs Motor Current Analog InputsAnalog Inputs 1 Digital I/O 2Digital & Analog I/O Boards Layout Analog OutputsDigital I/O Board Layout Analog Inputs 2Digital Output Board Layout Digital Output BoardsDigital Input Board Layout Digital Input BoardsDigital Input-Output Board Layout Digital In-Out BoardsAnalog Input Board Layout Analog Input BoardsAnalog Input Jumper Tables Channel SignalJP-13 JP-14 JP-15 JP-31 Analog Output Board Layout Analog Output BoardsMain Screen Main ScreenTop Status Bar Parameter Bar Unit Start Pop-Up Window Bottom Status Bar Splash Screen Navigation Buttons Menu ScreenMenu Screen Pulse Proportional Control Compressor ControlProportional Band & Setpoint Auto-CycleVFD One-Step Control Method Variable Frequency Drive VFDPumpdown Control Pulldown Control Capacity Slide Triggered Outputs Control ModeVolume Slide Position Offset Stop Load and Force UnloadLiquid Injection Load AnticipatingOil Control Compressor Control Alarms and Trips Setpoints Alarms and TripsAlarms and Trips Compressor Inhibits Safety Failure MessagesFalse Start Timer Setpoints TimersOil Separator Level #2 Safety Trip Delay Timers Blank Scheduling Setpoint Compressor SchedulingCompressor Scheduling Pressure Control Setpoints Compressor SequencingCFM Equipment List 10 4 / Blank Condenser Control Setpoint Condenser ControlStep Control Step Control Screen VFD Settings11 4 / Blank Digital Outputs Service OptionsAnalog Outputs Instruments Calibration Pressure and Temperature InputsRemote Capacity Motor CurrentAnalog Inputs 13 4 / Blank Capacity Slide Valve Potentiometer Slide CalibrationSlide Valve Actuator Calibration for Optical Style Motors Volume Slide Valve PotentiometerSlide Valve Operation Photochopper Command Shaft Rotation Required By Actuator Command Shaft RotationSlide Valve Troubleshooting Guide 1 Slide Valve Troubleshooting GuideSlide Valve Troubleshooting Guide 2 LED Blink Codes and Troubleshooting Guide 1 Slide Valve Actuator Troubleshooting Guide Blink CodePleted. The actuator will not move while this error code LED Blink Codes and Troubleshooting Guide 2Chart Operation Trend ChartTrend Data Storage Trend Setup Screen Setup15 4 / Blank Event list Columns Event List16 2 / Blank Input/Output Screen Input / Output17 2 / Blank Digital Inputs Auxiliary Input / OutputDigital Outputs Control 18 4 / Blank Time & Date ConfigurationUnits Anti-Recycle CommunicationsTouchscreen Model & Refrigerant Restart On Power FailureCompressor Sequencing LanguageOptional Function Selection Compressor ControlMotor Current Device Condenser ControlOil Pump Oil CoolingDigital Inputs Analog Inputs Analog Outputs Configuration 19 10 / Blank Save / Load Data BackupData Backup Migrate Factory Reset20 4 / Blank Checklist MaintenanceLog ChartApply User AccessManage Accounts LoginScreen Security Levels Security Access Levels22 4 / Blank Help Screen Screen FeaturesVersion Pop-Up Screen Twin Screw Control Screen Twin Screw ControlOperation Cool Compression Control Screen Cool Compression ControlCool Compression Control Functions Screen Control FunctionsOperational Differences from Single Screw Auto Load TimerCool Compression Control

20/20 specifications

Emerson 20/20 is an advanced platform designed for real-time data analytics, visualization, and operational optimization in industrial settings. This robust solution aims to empower organizations by providing actionable insights derived from their operational data, enabling enhanced decision-making and improved efficiency.

One of the standout features of Emerson 20/20 is its ability to integrate seamlessly with various sources of data, whether structured or unstructured. It consolidates information from different systems, such as historians, control systems, and ERP software, allowing users to gain a comprehensive view of their operations. This integration capability is crucial for businesses looking to maximize their data utilization without being confined to a single data source.

The platform employs powerful analytics tools that utilize machine learning and artificial intelligence technologies. These tools are designed to automatically identify patterns, anomalies, and trends in real-time. By leveraging predictive analytics, Emerson 20/20 helps organizations forecast potential issues before they escalate, allowing for proactive maintenance and minimizing downtime.

Emerson 20/20 also features user-friendly visualization dashboards, which provide customizable views tailored to individual user roles. This means that whether you are a plant manager, a process engineer, or an executive, you can access relevant data that speaks directly to your needs. These dashboards facilitate easier understanding of complex data sets, promoting informed decision-making across the organization.

One notable characteristic of Emerson 20/20 is its adaptability and scalability. Businesses of all sizes can implement the platform and scale its features according to their needs. This flexibility ensures that both small operations and large enterprises can derive value from the solution, making it an attractive option for various industries.

Additionally, the platform is designed with cybersecurity in mind, ensuring that data integrity and confidentiality are maintained. This aspect is increasingly important as industries become more interconnected and target more sophisticated cyber threats.

In summary, Emerson 20/20 stands out as a powerful tool for organizations seeking to harness their operational data effectively. With its advanced analytics capabilities, seamless integration, customizable visualization, and scalable design, it offers a comprehensive solution to optimize industrial performance and support data-driven decision-making. As businesses continue to navigate the complexities of modern operations, Emerson 20/20 provides the insights necessary to stay competitive and responsive to changing market demands.