Section 10 • Compressor Sequencing

Status Symbols:

Status symbols shows status of Slave compressors on the sequencing table. Please see Application Notes for more details.

Slave Compressor is detected but is not configured in the sequencing table.

Default, If slave Compressor is not present.

Slave Compressor is configured in sequencing table but is not configured in “Remote” mode.

Slave Compressor configured in sequencing table and is in ready to run state.

Slave Compressor is running with Alarm condition.

Slave Compressor stopped due to Error Condition.

Slave Compressor running at maximum capacity without any error.

Slave Compressor under active control of Master Compressor

Slave Compressor running into its stop timer, will be stopped.

Machine Stop Time:

Machine Stop timer shows the time in sec that the Master Compressor will hold before stopping slave compressor once (Stop ) decision is taken.

Refresh:

Compressor Sequencing table is automatically re- freshed every 1 minute. Pressing “Refresh” button refreshes the status of the Compressor Sequencing table on Master Compressor.

NOTE

Before Configuring Sequencing table on Master Compressor, log on to slave compressors one by one and enable sequencing in slave mode, put slave in remote mode. Then log on to Master Compressor and wait till all slaves show up their names under

equipment List.

Vission 20/20 • Operation and Service Manual •Vilter/Emerson • 35391SC 1.8.5153

10 – 3

Image 59
Contents Vission 20/20 micro-controller Page Table of Contents Digital I/O Board Layout Top Status Bar TOCCompressor Sequencing Event List Data Backup List of Tables and Figures END of TOC How to Use This Manual Compressor Amperage Load Limiting Operational Flow ChartsRequirements to Start Compressor Critical Compressor Run Logic at Compressor StartOperational Flow Charts 2 Voltage Source Installation RecommendationsProper Wiring Sizing Mixing Voltages DC signalsGrounding Correct Transformer Wiring Method Wiring MethodsBest Practices Overview Hardware ArchitectureDigital Input/Output I/O Board Description Type Digital I/O 1Refer to -2. Analog Inputs Motor Current Analog InputsAnalog Inputs 1 Digital I/O 2Digital & Analog I/O Boards Layout Analog OutputsDigital I/O Board Layout Analog Inputs 2Digital Output Board Layout Digital Output BoardsDigital Input Board Layout Digital Input BoardsDigital Input-Output Board Layout Digital In-Out BoardsAnalog Input Board Layout Analog Input BoardsAnalog Input Jumper Tables Channel SignalJP-13 JP-14 JP-15 JP-31 Analog Output Board Layout Analog Output BoardsMain Screen Main ScreenTop Status Bar Parameter Bar Unit Start Pop-Up Window Bottom Status Bar Splash Screen Navigation Buttons Menu ScreenMenu Screen Pulse Proportional Control Compressor ControlProportional Band & Setpoint Auto-CycleVFD One-Step Control Method Variable Frequency Drive VFDPumpdown Control Pulldown Control Capacity Slide Triggered Outputs Control ModeVolume Slide Position Offset Stop Load and Force UnloadLiquid Injection Load AnticipatingOil Control Compressor Control Alarms and Trips Setpoints Alarms and TripsAlarms and Trips Compressor Inhibits Safety Failure MessagesFalse Start Timer Setpoints TimersOil Separator Level #2 Safety Trip Delay Timers Blank Scheduling Setpoint Compressor SchedulingCompressor Scheduling Pressure Control Setpoints Compressor SequencingCFM Equipment List 10 4 / Blank Condenser Control Setpoint Condenser ControlStep Control Step Control Screen VFD Settings11 4 / Blank Digital Outputs Service OptionsAnalog Outputs Instruments Calibration Pressure and Temperature InputsRemote Capacity Motor CurrentAnalog Inputs 13 4 / Blank Capacity Slide Valve Potentiometer Slide CalibrationSlide Valve Actuator Calibration for Optical Style Motors Volume Slide Valve PotentiometerSlide Valve Operation Photochopper Command Shaft Rotation Required By Actuator Command Shaft RotationSlide Valve Troubleshooting Guide 1 Slide Valve Troubleshooting GuideSlide Valve Troubleshooting Guide 2 LED Blink Codes and Troubleshooting Guide 1 Slide Valve Actuator Troubleshooting Guide Blink CodePleted. The actuator will not move while this error code LED Blink Codes and Troubleshooting Guide 2Chart Operation Trend ChartTrend Data Storage Trend Setup Screen Setup15 4 / Blank Event list Columns Event List16 2 / Blank Input/Output Screen Input / Output17 2 / Blank Digital Inputs Auxiliary Input / OutputDigital Outputs Control 18 4 / Blank Time & Date ConfigurationUnits Anti-Recycle CommunicationsTouchscreen Model & Refrigerant Restart On Power FailureCompressor Sequencing LanguageOptional Function Selection Compressor ControlMotor Current Device Condenser ControlOil Pump Oil CoolingDigital Inputs Analog Inputs Analog Outputs Configuration 19 10 / Blank Save / Load Data BackupData Backup Migrate Factory Reset20 4 / Blank Checklist MaintenanceLog ChartApply User AccessManage Accounts LoginScreen Security Levels Security Access Levels22 4 / Blank Help Screen Screen FeaturesVersion Pop-Up Screen Twin Screw Control Screen Twin Screw ControlOperation Cool Compression Control Screen Cool Compression ControlCool Compression Control Functions Screen Control FunctionsOperational Differences from Single Screw Auto Load TimerCool Compression Control

20/20 specifications

Emerson 20/20 is an advanced platform designed for real-time data analytics, visualization, and operational optimization in industrial settings. This robust solution aims to empower organizations by providing actionable insights derived from their operational data, enabling enhanced decision-making and improved efficiency.

One of the standout features of Emerson 20/20 is its ability to integrate seamlessly with various sources of data, whether structured or unstructured. It consolidates information from different systems, such as historians, control systems, and ERP software, allowing users to gain a comprehensive view of their operations. This integration capability is crucial for businesses looking to maximize their data utilization without being confined to a single data source.

The platform employs powerful analytics tools that utilize machine learning and artificial intelligence technologies. These tools are designed to automatically identify patterns, anomalies, and trends in real-time. By leveraging predictive analytics, Emerson 20/20 helps organizations forecast potential issues before they escalate, allowing for proactive maintenance and minimizing downtime.

Emerson 20/20 also features user-friendly visualization dashboards, which provide customizable views tailored to individual user roles. This means that whether you are a plant manager, a process engineer, or an executive, you can access relevant data that speaks directly to your needs. These dashboards facilitate easier understanding of complex data sets, promoting informed decision-making across the organization.

One notable characteristic of Emerson 20/20 is its adaptability and scalability. Businesses of all sizes can implement the platform and scale its features according to their needs. This flexibility ensures that both small operations and large enterprises can derive value from the solution, making it an attractive option for various industries.

Additionally, the platform is designed with cybersecurity in mind, ensuring that data integrity and confidentiality are maintained. This aspect is increasingly important as industries become more interconnected and target more sophisticated cyber threats.

In summary, Emerson 20/20 stands out as a powerful tool for organizations seeking to harness their operational data effectively. With its advanced analytics capabilities, seamless integration, customizable visualization, and scalable design, it offers a comprehensive solution to optimize industrial performance and support data-driven decision-making. As businesses continue to navigate the complexities of modern operations, Emerson 20/20 provides the insights necessary to stay competitive and responsive to changing market demands.