Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Mos outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

!WARNING

To avoid fire, or shock, follow all wiring instructions carefully.

Any electrical work not described in these instructions should be done or approved by a licensed electrician.

How to Hang Your Ceiling Fan

!WARNING

The fan must be hung with at least 7' of clearance from floor to blades (Figure 6).

CEILING

!WARNING

Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.

AT LEAST

7'

Figure 6

FLOOR

 

!WARNING

The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs.

!WARNING

2. Carefully lift the fan from the foam pad and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 8). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 7).

!WARNING

Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.

NOTE: CEILING COVER,

 

SUPPLY WIRES AND

OUTLET

FAN WIRES OMITTED

BOX

FOR CLARITY.

 

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

Figure 8

HANGER BRACKET

1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 7).

OUTLET

BOX

HANGER BALL/

DOWNROD ASSEMBLY

!WARNING

To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and the hanger bracket.

TWO SCREWS

 

SUPPLIED WITH

HANGER

OUTLET BOX

 

BRACKET

Figure 7

TAB

5

 

Image 5
Contents Read and Save These Instructions Net Weight 11.1 LbsAdditional Safety Instructions for Installation Safety InstructionsHow to Put Your Tools Needed for AssemblyAttached to the switch housing plate, proceed to Step Unpacking InstructionsSwitch Housing Assembly Mounting Screws Electrical Requirements How to Hang Your Ceiling FanUsing Your Ceiling Fan How To Wire Your Ceiling FanFor Your Ceiling Fan Trouble ShootingMaintenanceAccessories 8100 W. Florissant, St. Louis, MO Repair Parts Listing CF703 and CF702 SeriesRepair Parts Listing CF704 Series