2.3 ELECTRICAL INSTALLATION.

The Models 396, 396VP, 397, 398, and 398VP are for use with a remote preamplifier. Each sensor comes with either a special 15 ft low noise coax cable or a Variopol (VP) con- nector, which is used with a mating Variopol cable. The cable should be handled carefully, and kept dry and free of corrosive chemicals at all times. Extreme care should be used to prevent the cable from being twisted, damaged or scraped by rough, sharp edges or surfaces. Please refer to Figures 2-7 thru 2-18 for wiring Models 396, 397, and 398.

FIGURE 2-7. Models 396, 397, and 398 Standard Wiring Option used with Models 1054A, 1054B, 2054, and Preamplifiers PN 22698-02 and 22698-03.

Please refer to Figures 2-19 thru 2-36 for wiring Models 396VP and 398VP.

DANGER

DO NOT CONNECT SENSOR CABLE TO POWER

LINES. SERIOUS INJURY MAY RESULT.

NOTE

Remove electrical tape or shrink sleeve from gray refer- ence wire before connecting wire to terminal.

FIGURE 2-8. Models 396, 397, and 398 Option -62 for Wiring to Models 1054, 1181, 2081, 54, 81, 3081, 4081, SoluComp, and 2700 Preamplifier (PN 23054-03). Also for use with remote Junction Box PN 23555-00.

15

Image 19
Contents Model PH/ORP SensorsEssential Instructions Hazardous Area InstallationList of Tables Table of ContentsList of Figures Cross Section Diagram of the TUpH Reference TechnologyTUpH Features and Applications Section Description and SpecificationsCross Section Diagram of the TUpH Reference Technology Model QUIK-LOC KIT Performance & Physical SpecificationsModel Ordering Information398 10 32 Model Mounting Accessories optional Part Number Description Safety Warning Section Installation2 inch Pipe Tee PN 2002011 with 1 inch threaded connections Dimensional Drawing For Models 396 Section 40039603 C Dimensional Drawings For Model 397 in the Quik-Loc Unit Electrical Installation 40039610 40038920 G 40039607 40039606 D 40039608 D 40039605 F 40039611 Section 21. Wiring Model 396VP and 398VP to 24. Wiring Model 396VP and 398VP to Model 28. Wiring Model 396VP and 398VP to 33. Wiring Model 396VP/398VP to Models 54/54e 36. Wiring Model 396VP-54 to Model 38. Wiring Models 396VP & 398VP to Model Xmt-P-XX-10 39. Wiring Models 396/397/398 to Model 5081-P Section Start UP and Calibration Calibration Using Buffer Solutions or Grab SamplesSensor Preparation Sensor is in Pressurized System Section MaintenanceTroubleshooting Probable Cause Remedy Section TroubleshootingGeneral Warranty RepairNON-WARRANTY Repair Section Return of MaterialWarranty Specifications subject to change without notice
Related manuals
Manual 40 pages 16.63 Kb

398, 397, 396VP, 398VP, 396 specifications

Emerson offers a wide range of advanced process control instruments, and among them, the Emerson 396, 398VP, 396VP, 397, and 398 stand out for their precision, reliability, and versatility. These models are designed to cater to the demanding needs of industrial applications, particularly in the areas of pressure, temperature, and flow measurement.

The Emerson 396 series focuses on providing robust pressure and temperature measurement solutions. One of its standout features is its digital manometer functionality, which allows for precise measurement of differential pressure. This makes it an excellent choice for HVAC applications and other industrial processes where accuracy is critical. The 396 model is equipped with advanced signal processing capabilities, allowing for the adjustment of sensitivities and ranges according to specific application needs.

Moving on to the 398VP and 396VP models, these variants incorporate advanced validation features that ensure data integrity and accuracy. They are designed with user-friendly interfaces that not only simplify operation but also enhance user experience. The 398VP model, in particular, is celebrated for its versatility, as it can operate in both electrical and pneumatic environments. Additionally, the model comes with integrated diagnostics, which simplifies maintenance by providing real-time data on operational status.

The Emerson 397 model focuses on flow measurement and control. It integrates technologies that minimize the impact of environmental factors on measurement accuracy. Its intelligent algorithms provide compensation for temperature and pressure fluctuations, ensuring consistent performance in varying conditions. This model is also compatible with various fieldbus protocols, facilitating easy integration into existing systems.

Finally, the Emerson 398 model is known for its high-performance digital operation. It includes features such as remote monitoring and control capabilities, which allow operators to manage processes from any location. The 398 is specifically designed to meet the rigorous requirements of industries like oil and gas, chemical, and power generation.

In summary, the Emerson 396, 398VP, 396VP, 397, and 398 models are equipped with cutting-edge technologies and features tailored for industrial efficiency, reliability, and accuracy. Their user-friendly interfaces, advanced diagnostics, and compatibility with modern communication protocols make them invaluable tools for engineers and operators in various sectors, enhancing overall productivity and performance.