Emerson 398VP, 396VP Section Return of Material, General, Warranty Repair, NON-WARRANTY Repair

Page 38

MODEL 396/396VP/397/398/398VP

SECTION 6.0

 

RETURN OF MATERIAL

SECTION 6.0

RETURN OF MATERIAL

6.1 GENERAL.

To expedite the repair and return of instruments, proper communication between the customer and the factory is important. Before returning a product for repair, call 1-949-757-8500 for a Return Materials Authorization (RMA) number.

6.2 WARRANTY REPAIR.

The following is the procedure for returning instru- ments still under warranty:

1.Call Rosemount Analytical for authorization.

2.To verify warranty, supply the factory sales order number or the original purchase order number. In the case of individual parts or sub-assemblies, the serial number on the unit must be supplied.

3.Carefully package the materials and enclose your “Letter of Transmittal” (see Warranty). If possible, pack the materials in the same manner as they were received.

4.Send the package prepaid to:

Rosemount Analytical Inc., Uniloc Division Uniloc Division

2400 Barranca Parkway Irvine, CA 92606

Attn: Factory Repair

RMA No. ____________

Mark the package: Returned for Repair

Model No. ____

6.3 NON-WARRANTY REPAIR.

The following is the procedure for returning for repair instruments that are no longer under warranty:

1.Call Rosemount Analytical for authorization.

2.Supply the purchase order number, and make sure to provide the name and telephone number of the individual to be contacted should additional information be needed.

3.Do Steps 3 and 4 of Section 6.2.

NOTE

Consult the factory for additional informa- tion regarding service or repair.

34

Image 38
Contents PH/ORP Sensors ModelHazardous Area Installation Essential InstructionsTable of Contents List of TablesCross Section Diagram of the TUpH Reference Technology List of FiguresSection Description and Specifications TUpH Features and ApplicationsCross Section Diagram of the TUpH Reference Technology Performance & Physical Specifications Model QUIK-LOC KITOrdering Information Model398 10 32 Model Mounting Accessories optional Part Number Description Section Installation Safety Warning2 inch Pipe Tee PN 2002011 with 1 inch threaded connections Dimensional Drawing For Models 396 Section 40039603 C Dimensional Drawings For Model 397 in the Quik-Loc Unit Electrical Installation 40039610 40038920 G 40039607 40039606 D 40039608 D 40039605 F 40039611 Section 21. Wiring Model 396VP and 398VP to 24. Wiring Model 396VP and 398VP to Model 28. Wiring Model 396VP and 398VP to 33. Wiring Model 396VP/398VP to Models 54/54e 36. Wiring Model 396VP-54 to Model 38. Wiring Models 396VP & 398VP to Model Xmt-P-XX-10 39. Wiring Models 396/397/398 to Model 5081-P Sensor Preparation Calibration Using Buffer Solutions or Grab SamplesSection Start UP and Calibration Section Maintenance Sensor is in Pressurized SystemSection Troubleshooting Troubleshooting Probable Cause RemedySection Return of Material Warranty RepairNON-WARRANTY Repair GeneralWarranty Specifications subject to change without notice
Related manuals
Manual 40 pages 16.63 Kb

398, 397, 396VP, 398VP, 396 specifications

Emerson offers a wide range of advanced process control instruments, and among them, the Emerson 396, 398VP, 396VP, 397, and 398 stand out for their precision, reliability, and versatility. These models are designed to cater to the demanding needs of industrial applications, particularly in the areas of pressure, temperature, and flow measurement.

The Emerson 396 series focuses on providing robust pressure and temperature measurement solutions. One of its standout features is its digital manometer functionality, which allows for precise measurement of differential pressure. This makes it an excellent choice for HVAC applications and other industrial processes where accuracy is critical. The 396 model is equipped with advanced signal processing capabilities, allowing for the adjustment of sensitivities and ranges according to specific application needs.

Moving on to the 398VP and 396VP models, these variants incorporate advanced validation features that ensure data integrity and accuracy. They are designed with user-friendly interfaces that not only simplify operation but also enhance user experience. The 398VP model, in particular, is celebrated for its versatility, as it can operate in both electrical and pneumatic environments. Additionally, the model comes with integrated diagnostics, which simplifies maintenance by providing real-time data on operational status.

The Emerson 397 model focuses on flow measurement and control. It integrates technologies that minimize the impact of environmental factors on measurement accuracy. Its intelligent algorithms provide compensation for temperature and pressure fluctuations, ensuring consistent performance in varying conditions. This model is also compatible with various fieldbus protocols, facilitating easy integration into existing systems.

Finally, the Emerson 398 model is known for its high-performance digital operation. It includes features such as remote monitoring and control capabilities, which allow operators to manage processes from any location. The 398 is specifically designed to meet the rigorous requirements of industries like oil and gas, chemical, and power generation.

In summary, the Emerson 396, 398VP, 396VP, 397, and 398 models are equipped with cutting-edge technologies and features tailored for industrial efficiency, reliability, and accuracy. Their user-friendly interfaces, advanced diagnostics, and compatibility with modern communication protocols make them invaluable tools for engineers and operators in various sectors, enhancing overall productivity and performance.