Emerson 396VP, 398VP Section Description and Specifications, TUpH Features and Applications

Page 5

MODEL 396/396VP/397/398/398VP

SECTION 1.0

 

DESCRIPTIONS AND SPECIFICATIONS

SECTION 1.0

DESCRIPTION AND SPECIFICATIONS

1.1 TUpH™ FEATURES AND APPLICATIONS.

Rosemount Analytical has achieved a new industry standard for the life expectancy of pH sensors with the TUpH Sensors. The low maintenance, disposable Models 396, 396VP, 397, 398, and 398VP TUpH Sensors offer long life and high performance in the measurement of pH in aqueous solutions in pipelines, open tanks, or ponds. These TUpH sensors feature a large area reference junction for maximum resistance to process coatings, generally found in dirty, high solid applications. In addition, the secondary helical refer- ence pathway serves as added protection from poi- soning ions. The simplified construction, designed with user convenience in mind, does not require elec- trolyte replenishment or any component replacement. All models feature a large glass bulb for increased resistance to the effects of aging for longer life. All models are available only without an integral pream- plifier. The preamplifier must be in a remote location or integral to the analyzer/transmitter. Models with a “VP” after the model number indicate the variopol connector is used on the sensor in place of the cable. In this case, a separate cable with a mating VP con- nector must be used. All models are compatible with all Rosemount Analytical and most manufacturers instruments.

The entire line of TUpH model sensors now incor- porate the new SILCORE technology contaminant barrier. This triple-seal barrier prevents moisture and material impurities from migrating to the pH sensor’s reference electrode’s metal lead wire. By preventing these contaminants from compromising the integrity of the pH measurement, sensor life is increased, espe- cially at higher temperatures where increased migra- tions occur. In addition, the SILCORE1 technology pro- vides added protection against sensor failure due to vibrations and shock by transferring damaging energy away from the glass-to-metal seal.

1.1.1Model 396 and 396VP TUpH Features and Applications.

The Models 396 and 396VP TUpH sensors are construct- ed of polypropylene and stain- less steel and is completely sealed by EP (ethylene propy- lene) to eliminate process intrusion. It is specifically

designed for improved life in harsh, dirty applications such as lime slurry waste treatment and paper machine headbox and pigment/dye applications where large quantities of suspended solids are present. Installation is easily achieved through a wide variety of

mounting configurations. The Model 396 features an optional front or rear 1 in. MNPT process connection for insertion, submersion, or flow through applications.

1.1.2Model 397 TUpH and Quik-Loc Features and Applications. The Model 397 is housed in a highly chemical resistant polypropylene body and completely sealed with EP to eliminate process intru- sion. The Model 397 body is

specifically designed for use with the Quik-Loc Kit which consists of an adapter and coupler. The PEEK (polyetheretherketone) adapter enables the Model 397 sensor to fit into a 1 in. MNPT Dixon coupler for quick and easy removal without sensor cable twisting. The 316 stainless steel DIxon coupler is sealed with EP and features locking arms. The Quik-Loc Kit is not recom- mended for use in processes with hazardous, corro- sive, or strong oxidizing chemicals due to a risk of spray and bodily hazards.

1.1.3Model 398 and 398VP TUpH

Features and Applications.

The chemical-resistant con- struction of Tefzel, titanium, and the TUpH reference junc- tion make the Models 398 and 398VP the ideal sensors for measuring pH in harsh process liquids. Use Model

398 or 398VP to measure pH in sour water strippers, in pulp bleaching towers that use chlorine dioxide, and in process streams containing a variety of organic sol- vents.

Models 398 and 398VP use the highest quality mate- rials to provide superior chemical resistance. The sen- sors are housed in a titanium tube and features an optional 1 inch MNPT process connector for insertion, submersion, or flow-through applications. The molded Tefzel TUpH construction is offered with a choice of seals (Viton, EPDM, or Kalrez). Combining high qual- ity materials with the TUpH reference technology and ACCUGLASS1 pH bulb allows for ultimate chemical resistance and makes Models 398 and 398VP the perfect choice for measuring pH in harsh, demanding processes.

1 ACCUGLASS and Silcore are trademarks of Rosemount Analytical

1

Image 5
Contents Model PH/ORP SensorsEssential Instructions Hazardous Area InstallationList of Tables Table of ContentsList of Figures Cross Section Diagram of the TUpH Reference TechnologyTUpH Features and Applications Section Description and SpecificationsCross Section Diagram of the TUpH Reference Technology Model QUIK-LOC KIT Performance & Physical SpecificationsModel Ordering Information398 10 32 Model Mounting Accessories optional Part Number Description Safety Warning Section Installation2 inch Pipe Tee PN 2002011 with 1 inch threaded connections Dimensional Drawing For Models 396 Section 40039603 C Dimensional Drawings For Model 397 in the Quik-Loc Unit Electrical Installation 40039610 40038920 G 40039607 40039606 D 40039608 D 40039605 F 40039611 Section 21. Wiring Model 396VP and 398VP to 24. Wiring Model 396VP and 398VP to Model 28. Wiring Model 396VP and 398VP to 33. Wiring Model 396VP/398VP to Models 54/54e 36. Wiring Model 396VP-54 to Model 38. Wiring Models 396VP & 398VP to Model Xmt-P-XX-10 39. Wiring Models 396/397/398 to Model 5081-P Sensor Preparation Calibration Using Buffer Solutions or Grab SamplesSection Start UP and Calibration Sensor is in Pressurized System Section MaintenanceTroubleshooting Probable Cause Remedy Section TroubleshootingNON-WARRANTY Repair Warranty RepairSection Return of Material GeneralWarranty Specifications subject to change without notice
Related manuals
Manual 40 pages 16.63 Kb

398, 397, 396VP, 398VP, 396 specifications

Emerson offers a wide range of advanced process control instruments, and among them, the Emerson 396, 398VP, 396VP, 397, and 398 stand out for their precision, reliability, and versatility. These models are designed to cater to the demanding needs of industrial applications, particularly in the areas of pressure, temperature, and flow measurement.

The Emerson 396 series focuses on providing robust pressure and temperature measurement solutions. One of its standout features is its digital manometer functionality, which allows for precise measurement of differential pressure. This makes it an excellent choice for HVAC applications and other industrial processes where accuracy is critical. The 396 model is equipped with advanced signal processing capabilities, allowing for the adjustment of sensitivities and ranges according to specific application needs.

Moving on to the 398VP and 396VP models, these variants incorporate advanced validation features that ensure data integrity and accuracy. They are designed with user-friendly interfaces that not only simplify operation but also enhance user experience. The 398VP model, in particular, is celebrated for its versatility, as it can operate in both electrical and pneumatic environments. Additionally, the model comes with integrated diagnostics, which simplifies maintenance by providing real-time data on operational status.

The Emerson 397 model focuses on flow measurement and control. It integrates technologies that minimize the impact of environmental factors on measurement accuracy. Its intelligent algorithms provide compensation for temperature and pressure fluctuations, ensuring consistent performance in varying conditions. This model is also compatible with various fieldbus protocols, facilitating easy integration into existing systems.

Finally, the Emerson 398 model is known for its high-performance digital operation. It includes features such as remote monitoring and control capabilities, which allow operators to manage processes from any location. The 398 is specifically designed to meet the rigorous requirements of industries like oil and gas, chemical, and power generation.

In summary, the Emerson 396, 398VP, 396VP, 397, and 398 models are equipped with cutting-edge technologies and features tailored for industrial efficiency, reliability, and accuracy. Their user-friendly interfaces, advanced diagnostics, and compatibility with modern communication protocols make them invaluable tools for engineers and operators in various sectors, enhancing overall productivity and performance.