Chauvet IEC 60825-1:2007, model EN manual Master/Slave Mode, Slave units

Page 16

Master/Slave Mode

The Master/Slave mode allows a single Eclipse™ RGB unit (the “master”) to control the actions of one or more Eclipse™ RGB units (the “slaves”) without the need of a DMX controller. The master unit will be set to operate in either Automatic or Sound Active mode, while the slave units will be set to operate in Slave Mode. Once set and connected, the slave units will operate in unison with the master unit.

Configure the units as indicated below.

Slave units:

1.Press <MENU> repeatedly until SLA shows on the display.

2.Press <ENTER> to accept.

3.Set the DMX address to 001.

4.Connect the DMX input of the first slave unit to the DMX output of the master unit.

5.Connect the DMX input of the subsequent slave units to the DMX output of the previous slave unit.

6.Finish setting and connecting all the slave units.

Master unit:

1.Set the master unit to operate in either Automatic or Sound mode.

2.Make the master unit the first unit in the DMX daisy chain.

Configure all the slave units before connecting the master unit to the DMX daisy chain.

Never connect a DMX controller to a DMX string configured for Master/Slave operation because the controller may interfere with the signals from the master unit.

Do not connect more than 31 slave units to the master unit.

The lasers cannot be turned off. They can be set to a slow strobe.

At higher rotation speeds, the operation noise may increase from the product. This is normal.

Eclipse™ RGB User Manual

16

12/20/2011

Image 16
Contents Page Table of Contents Before YOU Begin What Is IncludedUnpacking Instructions Safety Instructions Non Interlocked Housing Warning Laser Safety NotesLaser Safety Label Reproduction Laser Emission Data Laser Compliance StatementIntroduction Product OverviewProduct Dimensions AC Power SetupMounting Proper Usage Control Panel Operation Operating InstructionsMenu Map Configuration DMX Starting Address DMX Channel Assignments and Values 12-CHPage Master/Slave Mode Slave unitsGeneral Troubleshooting Returns ProcedureTechnical Specifications Power