Porter-Cable LR1100 Specifications, Troubleshooting, Recalibration On the jobsite, Made In China

Page 9

Specifications

Accuracy: +/- 1/8" @ 100' (radius)

Self-leveling:Level range +/- 10°; flashing out-of-level indicator

Remote Control: 3 speeds (low, medium & high); range – 100' radius and 200' diameter

Range: Laser visibility up to 100' (indoor & outdoor – no detector required); full 360° rotation

Pendulum Lock: Protects pendulum during transportation and storage for added durability

Line Generation Feature: Converts laser beam to line of bright dots

Recalibration: On the jobsite

Environmental: Dust, dirt and water resistant

Laser Diode: Class IIIA 635nm

Tripod Mount: 1/4" x 20 & 5/8" x 11, (can be used without tripod; tripod not included)

Warranty: 1 year limited

Power Supply: Base unit – 4 “AA” batteries; remote control – 9 volt battery (not included)

Made In China

Troubleshooting

When the…

LED does not come on when Lens Cover is up.

LED and Laser blink continuously.

Remote Control will not drive the Base Unit.

Laser & LED shut off without warning blinks.

Base Unit will not move on Adjusting Base.

The batteries in the Base Unit may need to be changed. Change the batteries, then turn the Base Unit on again.

Laser is out-of-level, or has been knocked out-of- level. Move the Base Unit on the Adjusting Base until both the LED and Laser quit blinking. Use the Remote Control to rotate the Base Unit 360°, making sure the Laser/LED do not blink at any time during the rotation.

Change the battery in the Remote Control. If the problem persists, change the batteries in the Base Unit.

Check batteries in the Base Unit. Prolonged exposure to extremely high temperatures (120° F +) may cause the laser to overheat. This will cause the self- protection circuit in the Base Unit to shut down.

The Base Unit has been mounted to a screw longer than 5/8". This could cause damage to the Adjusting Base.

9

Image 9
Contents Laser Level Self-Leveling, Remote-ControlledGeneral Safety Rules Rotary Level Features Base Unit AssemblyFunctional Description ForewordOperation Quick Guide to Using Rotary LevelFinding The Laser Dot Using the Remote ControlBase Unit 4 AA Alkaline Batteries Battery replacementRecalibration Page Troubleshooting SpecificationsRecalibration On the jobsite Made In ChinaLine Generating Feature User SafetyFCC Statement Keep Tool Clean General MaintenanceBattery Service and RepairsAccessories Canadian PORTER-CABLE Delta Service Centers