Spectra GL612 manual Automatic Axis Alignment only GL622, Activating/Deactivating Standby mode

Page 12

Automatic Axis Alignment (only GL622)

Automatic Axis Alignment mode adjusts automatically the direction the grade axis is pointing to the receiver’s location by an electronically simulation of rotating the unit on its base to match the hub. Using Axis Alignment, the laser axis can be aligned to one direction hub (up to 80 m (260 ft) located on one axis at each side of the laser.

1.Set up the laser over the reference point.

2.Place the grade rod with the attached HL750 receiver at the desired direction hub.

3.Use the sighting guides on the top of the laser to align the laser to the receiver. Turn the laser on the tripod until it is roughly aligned to the receiver’s position (the alignment range for both axes is +/-40°).

4.Press and release the MENU button at the Standard Display and select Axis Align.

5.Select the desired axis then press button 4 to start Axis Align.

Note: Adjusting the receiver into the beam before starting the automatic Axis Alignment reduces the time needed for finishing the alignment.

Activating/Deactivating Standby mode

Press and release the MENU button at the Standard Display and select Standby.

Pressing and releasing button 4 activates the Standby mode.

The self-leveling will be stopped and the beam will be turned off while the HI alert is still active. The display shows the standby symbol and the Level/Standby LED flashes red every 5 seconds.

To deactivate Standby mode and restore full operation of the laser, press and release button 4.

Start Reference Check

Before starting some grade work which is very sensitive an additional Reference Check can be started manually. Press and release the MENU button at the Standard Display and select Reference Check.

Pressing and releasing button 4 starts the Reference Check considering the current temperature inside the housing. While the rotor checks the correct position the rotation will be stopped.

Setting Menu

Press and release the MENU button at the Standard Display and select Settings.

Press and release button 4 to open the Setting Menu; select the desired function then press button 4 to open the selected submenu function OR start the selected function.

Please see the Setting Menu details at the end of the user guide.

10

Image 12
Contents GL622/GL612 North & Latin America Africa & Middle East EuropeAsia-Pacific ChinaTable of Contents For Your Safety ComponentsHOW to USE the Laser System Powering the Laser Recharging the BatteriesLaser Setup Features and FunctionsTurning On/Off the laser Standard Features Grade entering Step and Go mode Grade entering Digit Select mode DefaultUsing the Rotation mode Manual modeSpecial Menu Features Menu Functions Radio controlled Page Automatic PlaneLok mode Automatic Grade Match Activating/Deactivating Standby mode Setting MenuAutomatic Axis Alignment only GL622 Start Reference CheckService InfoSpecial Features Vertical Setup Line Scan PairingPairing the transmitter with remote control Pairing the transmitter with receiverMask mode Grade Entry Grade DisplaySensitivity Selection HI-alert SelectionSet Password Password On/OffUser Name Radio RF ChannelCalibration Select LanguageChecking Calibration of the Y- and X-Axes Checking Calibration of the Z-vertical AxisTroubleshooting Error codes Description SolutionCleaning and Maintenance Protecting the UnitProtecting the Environment Technical Data Remote Control RC602Declaration of Conformity GL622/GL612ELECTRO-MAGNETIC Compatibility