Spectra GL612 manual Troubleshooting, Error codes Description Solution

Page 19

Troubleshooting

Any error message can be deleted with a short press of button 4 (OK). The table shows the related description and possible solutions. The next service center should be contacted if a different error message as shown at the table will be displayed.

Error codes

Description

Solution

 

 

 

21

Temporary EEprom problem

Repeat pairing and re-enter the

 

 

customer settings

 

 

 

120

HI alert - Unit Heigt changed

Check laser beam elevation after

 

 

deleting the HI alert

130

Mechanical Limit during Axis

Re-align the closer to the

 

Alignment, Grade Match or Spot

alignment point; check if existing

 

Match

slope is above +/-25%

131

Rake Angle Limit

Re-align the unit closer to the

 

 

alignment point

 

 

 

140

Laser beam blocked

Make sure there are no

 

 

obstacles between the

 

 

transmitter and the HL750

 

 

 

141

Time Out - Function could not be

Check radio operating range/

 

completed in the allowed time

connection; check stable laser

 

 

setup

 

 

 

150

No receiver - Receiver not

Make sure the receiver is on and

 

available for single axis

paired

 

automatic function

 

152

No receiver - The laser searched

Check the operating range for

 

for the receiver but could not

auto function and restart the auto

 

find it

alignment

153

Lost Receiver - The laser

Check the operating range for

 

searched and found the receiver

auto function and restart the auto

 

but then lost it

alignment

160

X or Y level sensor defect

Contact service center

 

 

 

17

Image 19
Contents GL622/GL612 China North & Latin America Africa & Middle EastEurope Asia-PacificTable of Contents Components For Your SafetyRecharging the Batteries HOW to USE the Laser System Powering the LaserFeatures and Functions Laser SetupTurning On/Off the laser Grade entering Digit Select mode Default Standard Features Grade entering Step and Go modeManual mode Using the Rotation modeSpecial Menu Features Menu Functions Radio controlled Page Automatic PlaneLok mode Automatic Grade Match Start Reference Check Activating/Deactivating Standby modeSetting Menu Automatic Axis Alignment only GL622Info ServicePairing Special Features Vertical Setup Line ScanPairing the transmitter with receiver Pairing the transmitter with remote controlMask mode HI-alert Selection Grade EntryGrade Display Sensitivity SelectionRadio RF Channel Set PasswordPassword On/Off User NameChecking Calibration of the Z-vertical Axis CalibrationSelect Language Checking Calibration of the Y- and X-AxesError codes Description Solution TroubleshootingProtecting the Unit Cleaning and MaintenanceProtecting the Environment GL622/GL612 Technical DataRemote Control RC602 Declaration of ConformityELECTRO-MAGNETIC Compatibility