Spectra Complete Calibration Guide for Laser Levels - GL612 & GL622

Page 18

Select Language

Select the Language icon and press and release button 4 to open the Language menu.Use button 5 to 8 to select the required local language (EN, DE, IT, FR, ES, PT, NL, DA, NO, SV, FI, PL, TR, CZ). Press and release button 4 to store the selected Language; unit falls back to the standard menu.

CALIBRATION

Checking Calibration of the Y- and X-Axes

1.Set up the laser 30 m (100 ft) from a wall and allow it to level.

2.Set the grade to 0.000% in both axes.

3.Raise/lower the receiver until you get an on-grade reading for the +Y axis. Using the on-grade marking notch as a reference, make a mark on the wall.

Note: For increased precision, use the fine-sensitivity setting (1.5 mm/ 1/16 in.) on the receiver.

4.Rotate the laser 180° (-Y axis toward the wall) and allow the laser to re-level.

5.Raise/lower the receiver until you get an on-grade reading for the –Y/axis. Using the on-grade marking notch as a reference, make a mark on the wall.

6.Measure the difference between the two marks. If they differ more than 3 mm at 30 m (1/8 inch at 100 feet), the laser needs calibrating.

7.After checking the Y-axis, rotate the laser 90°. Repeat the above starting with the + X axis facing the wall.

Checking Calibration of the Z-(vertical) Axis

To check vertical calibration, you need a plumb bob with at least 10m (30ft) of string.

1.Suspend the plumb bob in front of a house i.e., attached to a window frame whose window height is at least 10m (30ft).

2.Set up the laser in vertical so that the laser beam strikes the receiver’s on-grade position at the top of the string.

3.Look for any deviation using the receiver from the top of the string to the bottom of it. If the deviation is more than 1mm (<1/16 in.), the vertical axis needs calibrating.

Note: If calibration is required, please, refer to the calibration instructions on our Trimble website www.trimble.com/support.shtml.

16

Image 18
Contents GL622/GL612 Asia-Pacific North & Latin America Africa & Middle EastEurope ChinaTable of Contents For Your Safety ComponentsHOW to USE the Laser System Powering the Laser Recharging the BatteriesLaser Setup Features and FunctionsTurning On/Off the laser Standard Features Grade entering Step and Go mode Grade entering Digit Select mode DefaultUsing the Rotation mode Manual modeSpecial Menu Features Menu Functions Radio controlled Page Automatic PlaneLok mode Automatic Grade Match Automatic Axis Alignment only GL622 Activating/Deactivating Standby modeSetting Menu Start Reference CheckService InfoSpecial Features Vertical Setup Line Scan PairingPairing the transmitter with remote control Pairing the transmitter with receiverMask mode Sensitivity Selection Grade EntryGrade Display HI-alert SelectionUser Name Set PasswordPassword On/Off Radio RF ChannelChecking Calibration of the Y- and X-Axes CalibrationSelect Language Checking Calibration of the Z-vertical AxisTroubleshooting Error codes Description SolutionCleaning and Maintenance Protecting the UnitProtecting the Environment Declaration of Conformity Technical DataRemote Control RC602 GL622/GL612ELECTRO-MAGNETIC Compatibility