Husky FP2205 operating instructions Oilless Compressors Troubleshooting Chart

Page 6

Oilless Compressors

Troubleshooting Chart

SymptomPossible Cause(s)Corrective Action

 

Compressor will not run

1. No electrical power

1.

Plugged in? Check fuse/breaker or motor overload

 

 

2.

Breaker open

2.

Reset, determine cause of problem

 

 

3.

Pressure switch bad

3.

Replace

 

 

 

4.

Check valve defective

4.

Remove and replace check valve

 

 

 

 

! DANGER

Do not disassemble check valve

 

 

 

 

with air in tank; bleed tank

 

 

 

 

 

 

Motor hums but cannot

1. Poor contacts, line voltage incorrect

1.

Check connections, check with voltmeter

 

run or runs slowly

2. Shorted or open motor winding

2.

Replace motor

 

 

 

3.

Defective check valve or unloader

3.

Replace or repair

 

 

 

 

 

! DANGER

Do not disassemble check valve

 

 

 

 

with air in tank; bleed tank

 

 

 

 

 

 

 

Fuses blow/circuit

1. Incorrect size fuse, circuit overloaded

breaker trips repeatedly

 

! CAUTION

2. Defective check valve or unloader

Never use an extension cord with this product

1.Check for proper fuse, use time-delay fuse. Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit

2.Replace or repair

! DANGER

Do not disassemble check valve

with air in tank; bleed tank

Tank pressure drops when compressor shuts off

1.

Loose connections (fittings, tubing,

1.

Check all connections with soap and water solution

 

etc.)

 

 

and tighten

 

2.

Loose drain cock

2.

Tighten

 

3.

Check valve leaking

3.

Disassemble check valve assembly, clean or replace

 

 

 

 

 

Do not disassemble check valve

 

 

 

! DANGER

 

 

 

with air in tank; bleed tank

 

 

 

 

Air output lower than normal/low discharge pressure

1.

Air leaks in piping (on machine or in

1.

Replace leaking components or tighten as necessary

 

outside system)

 

 

2.

Piston ring broken

2.

Replace

6

Image 6
Contents Description Safety GuidelinesGeneral Safety Information UnpackingAssembly InstallationOilless Compressors Operation Electrical InstallationWiring FP2205 SeriesMoisture in Compressed AIR Asme Safety ValveLubrication Regulator KnobMaintenance StorageOilless Compressors Troubleshooting Chart Short powerful bursts Tool Recommendations for this Air CompressorLimited Warranty Husky Air Compressor by Campbell Hausfeld Oilless Compressors FP2205 SeriesGénéralités Sur La Sécurité Directives De SécuritéDéballage Série FP2205Avertissement Nejamais Généralités Sur La Sécurité SuiteAssemblage Compresseurs Sans HuileAvertissement brancher Installation DE FilsFonctionnement Série FP2205Fonctionnement Suite Avertissement enleverManomètre DU Réservoir EntretienManomètre DE Sortie Outil GraissageCompresseurs Sans Huile Guide de Dépannage Taille de fusible incorrect, surchargeOutils NON Recommandés Outils Recommandés Pour Ce Compresseur D’AirOutils Recommandés Pour UNE Utilisation Continue Guide de Dépannage SuiteCompresseurs Sans Huile Série FP2205 LA Présente Garantie NE Couvre PASAdvertencia indica que DescripciónMedidas de Seguridad Para DesempacarAdvertencia use el Advertencia NuncadebeEnsamblaje Compresores Sin AceiteFuncionamiento InstalaciónAdvertencia cone Serie FP2205Advertencia el mango Almacenamiento MantenimientoLubricacion Manometro DEL TanqueCompresores Sin Aceite Guía de Diagnóstico de Averías Chequeo purgue el aire del tanqueHerramientas Recomendadas Para USO Continuo Guía de Diagnóstico de Averías ContinuaciónRecomendaciones De Herramientas Para Este Compresor De Aire Herramientas no RecomendadasCompresores Sin Aceite Serie FP2205 LO QUE no Esta Cubierto POR Esta Garantia