Oilless Compressors
Troubleshooting Chart
SymptomPossible Cause(s)Corrective Action
| Compressor will not run | 1. No electrical power | 1. | Plugged in? Check fuse/breaker or motor overload | ||
|
| 2. | Breaker open | 2. | Reset, determine cause of problem | |
|
| 3. | Pressure switch bad | 3. | Replace |
|
|
| 4. | Check valve defective | 4. | Remove and replace check valve | |
|
|
|
| ! DANGER | Do not disassemble check valve | |
|
|
|
| with air in tank; bleed tank | ||
|
|
|
|
| ||
| Motor hums but cannot | 1. Poor contacts, line voltage incorrect | 1. | Check connections, check with voltmeter | ||
| run or runs slowly | 2. Shorted or open motor winding | 2. | Replace motor |
| |
|
| 3. | Defective check valve or unloader | 3. | Replace or repair |
|
|
|
|
| ! DANGER | Do not disassemble check valve | |
|
|
|
| with air in tank; bleed tank | ||
|
|
|
|
|
|
|
Fuses blow/circuit | 1. Incorrect size fuse, circuit overloaded |
breaker trips repeatedly |
|
! CAUTION
2. Defective check valve or unloader
Never use an extension cord with this product
1.Check for proper fuse, use
2.Replace or repair
! DANGER | Do not disassemble check valve |
with air in tank; bleed tank |
Tank pressure drops when compressor shuts off
1. | Loose connections (fittings, tubing, | 1. | Check all connections with soap and water solution | ||
| etc.) |
|
| and tighten |
|
2. | Loose drain cock | 2. | Tighten |
| |
3. | Check valve leaking | 3. | Disassemble check valve assembly, clean or replace | ||
|
|
|
|
| Do not disassemble check valve |
|
|
| ! DANGER | ||
|
|
| with air in tank; bleed tank | ||
|
|
|
|
Air output lower than normal/low discharge pressure
1. | Air leaks in piping (on machine or in | 1. | Replace leaking components or tighten as necessary |
| outside system) |
|
|
2. | Piston ring broken | 2. | Replace |
6