Sears 200.71240 operating instructions Setting the Controls

Page 13

11.operating instructions

11.1Follow steps in section 6 or 7 for hookup and disconnect instructions, and precautions.

SETTING THE CONTROLS

All controls for your charger are located on the front of the unit. Follow these instructions to obtain the accurate charge level for your battery.

11.2TIMER: The main function of the timer is to prevent over charging while al- lowing the battery time to obtain a satisfactory charge. To properly set the timer, you must know the size of the battery in ampere hours or reserve capacity in minutes, and the state of charge. Often, the state of charge

is not known, which is why the timer is limited to 2.25 hours. With the aid of a battery load tester, the state of charge can be obtained within a few seconds. For example, the average size automotive battery at a 50% state of charge, will require 1 to 1.5 hours of charging at the 50 amp rate to reach the full charge state. For the same battery with the timer set to its maximum of 2.25 hours, over charging will occur, but is unlikely to cause harm to the battery. When the charge state is unknown, start out with a timer setting of 1 hour or less.

11.3HOLD: This function allows continuous operation. Use when charging for more than 2.25 hours (usually when the 2 amp charge rate is selected).

Stop charging when the battery is fully charged.

11.4Rotary switch: Use the rotary switch to select the charge rate or engine start setting required.

11.5Ammeter: Indicates the amount of current measured in amperes that is being drawn by the battery. For example, in the 50 amp charge rate, a typical discharged battery will initially draw approximately 50 amps. As the battery continues to charge, current will taper to 15 to 20 amps at full charge. The Start area of the meter indicates a high rate of current be- ing drawn from the charger. When cranking an engine, the starter motor draws upwards to 250-300 amps. The meter needle will be at the extreme right side of the start area. Sometimes, for the first few minutes of its charge, the battery will draw more than 50 amps; in this case, the needle may be within, but not all the way over, to the right side of the start area. The 2 amp charge rate may not indicate activity on the meter. The meter does not have the resolution to display this low rate.

11

Image 13
Contents OPERATOR’S Manual Battery Charger Table of Contents Important Safety Instructions Page Preparing to Charge DC Connection PrecautionsCharger Location Follow These Steps When Battery is Installed in ve- hicle Page Grounding and AC Power Cord Connection Instructions Grounding Methods Parts Tools Needed Volt Selector Switch Ammeter Clamps TimerPage Page Setting the Controls Charge Rate Battery SIZE/RATING Charging Time Hours AMPSpecific Gravity Percent of Charge Needed Hydrometer or Electronic MethodUsing the engine start feature Problem Possible Cause SOLUTION/REASONS