Sears 200.71240 operating instructions Problem Possible Cause SOLUTION/REASONS

Page 17

16.troubleshooting

PROBLEM

POSSIBLE CAUSE

SOLUTION/REASONS

No reading on the am-

Clamps are not making a

Check for poor connec-

meter.

good connection.

tions to battery and frame.

 

 

Make sure connecting

 

 

points are clean.

 

2-amp charge rate is be-

Ammeter may show no

 

ing used.

activity at the 2-amp

 

 

charge rate.

No reading on ammeter.

No power at receptacle.

Check for open fuse or

Fan inside wheel charger

 

circuit breaker supplying

appears to not be work-

 

AC outlet.

ing.

AC cord and/or extension

Check power cord and

 

 

cord is loose.

extension cord for loose

 

 

fitting plug.

Circuit breaker in charger

Shorted battery clamps.

Circuit breaker cycles

cycles on and off with a

 

when current draw is

clicking sound.

 

too high. Separate the

 

 

clamps. Check for worn

 

 

cables and replace if

 

 

needed.

 

Shorted battery.

Have battery tested by a

 

 

Sears or other qualified

 

Charger leads reversed.

service dealer.

 

Correct Connections.

 

Volt/Amp Selector Switch

 

Correct Volt/Amp Selector

 

set to the START position.

 

 

setting.

Short start cycle when

Drawing more than 250

Crank time varies with the

cranking engine.

amps for a period of 3

amount of current drawn.

 

seconds or less.

If cranking draws more

 

 

than 250 amps, crank

 

 

time may be less than 3

 

 

seconds.

 

Failure to wait for 4

Wait 4 minutes before

 

minutes (240 seconds)

next crank.

 

between cranks.

 

Ammeter reads less than

Extension cord too long or

Use shorter or heavier

selected charge rate when

wire gauge too small.

gauge extension cord.

charging a discharged

Weak cell or sulfated plate

Sulfated battery will

battery.

 

in battery.

eventually take a normal

 

 

charge if left connected. If

 

 

the battery will not take a

 

 

charge, have it tested by

 

 

a Sears or other qualified

 

 

service dealer.

 

Battery is only partially

Continue charging battery.

 

discharged.

 

Charger makes a loud

Transformer laminations

Continue charging. Buzz

buzz or hum.

vibrate (buzz).

is not abnormal.

 

Shorted diode (hum).

Have charger tested by a

 

 

Sears or other qualified

 

 

service dealer.

If the above solutions do not eliminate the problem call toll-free from anywhere in the U.S.A.

1-800-SEARS-64 (1-800-732-7764)

7 AM to 4:30 PM Central Time Monday through Friday

15

Image 17 Contents
OPERATOR’S Manual Battery Charger Table of Contents Important Safety Instructions Page Charger Location DC Connection PrecautionsPreparing to Charge Follow These Steps When Battery is Installed in ve- hicle Page Grounding and AC Power Cord Connection Instructions Grounding Methods Parts Tools Needed Volt Selector Switch Ammeter Clamps TimerPage Page Setting the Controls Charge Rate Battery SIZE/RATING Charging Time Hours AMPSpecific Gravity Percent of Charge Needed Hydrometer or Electronic MethodUsing the engine start feature Problem Possible Cause SOLUTION/REASONS