Emerson kf220tzg00 owner manual Scroll

Page 9

BP7307AuthorizedLarissa KF220Emerson1/9/06 Fan8:36 AMDealerP ge 9www.NovaLightingStore.com 800-860-1207

SCROLL

COLLAR

SETSCREW

GROMMET

COUPLING

COVER

MOTOR

HOUSING

Figure 9

SCROLL

RETAINING

SCREW

DOWNROD

SCROLL

DOWNROD

!WARNING

It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.

18. Place the ceiling cover over the downrod. Then reinstall the hanger ball (Figure 10) on the downrod as follows. Route the three 80” motor leads through the hanger ball and slide the hanger ball over the downrod. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.

15. Unscrew the three scroll retaining screws from the scroll collar. Using the hex wrench (supplied), unscrew the setscrew in the scroll collar until it clears the inside of the collar. Slide the collar over the downrod (Figure 9), and position the collar 7 or 8- inches above the coupling cover, then tighten the setscrew.

PIN

HANGER BALL

DOWNROD

SETSCREW

16.Align one downrod scroll with one of the slots in the scroll collar and secure the scroll in place using a scroll retaining screw (previously removed) (Figure 9). Repeat this procedure for the remaining two downrod scrolls.

NOTE: The downrod scrolls must properly mate with the slots in the scroll collar to assure proper alignment. Securely tighten the screws.

17.Loosen the setscrew and slide the

scroll collar down the downrod until the decorative scrolls rest upon the top of the motor housing (Figure 9). Tighten the setscrew.

CEILING

COVER

Figure 10

19.The fan comes with blue, black and white leads that are 80” long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2” from end of leads.

20.You have now completed the initial assembly of your new ceiling fan. You can now proceed with hanging and wiring your fan.

9

Emerson Fans Available at www.NovaLightingStore.com 800-860-1207

Image 9
Contents Larissa Safety Instructions Additional Safety Instructions for InstallationDate Code Unpacking Instructions MaterialsEmerson Electrical Requirements Ceiling Fan Procedures How to Assemble Your Ceiling FanGeneral Switch CUP Plate Switch CUP Assembly PIN Hanger Ball Downrod Setscrew Hairpin Scroll TAB How to Hang Your Ceiling FanStud How to Wire Your Ceiling FanSW101 FAN/LIGHT Wall Control Supplied Black To HOT Setting Operating Frequency of Wall Control and Receiver Installation of Wall ControlDo not connect any neutral white Required WAY WIRlNG Diagram NEW ConstructionOperating Your Ceiling Fan On position.REVERSING SwitchMaintenanceAccessories Important Care InstructionsFor your Ceiling Fan Trouble Probable Cause Suggested Remedy Trouble ShootingHOW to Order Repair Parts Repair PartsRepair Parts Listing KeyModel No Description What The Warranty Covers Limited Warranty

kf220tzg00 specifications

The Emerson KF220TZG00 is a highly efficient and versatile temperature control solution designed for various commercial and industrial applications. Aimed primarily at improving energy efficiency and ensuring precise refrigeration and HVAC system operation, this innovative product stands out in the marketplace for its performance and technological features.

One of the main features of the KF220TZG00 is its advanced temperature control technology. It uses high-precision sensors to monitor temperature fluctuations, providing real-time data and enabling quick adjustments to maintain optimal performance. This level of accuracy is essential for industries that require stringent temperature regulations, such as food storage and pharmaceuticals.

The KF220TZG00 also incorporates energy-saving technologies that help organizations reduce their operational costs. By optimizing compressor operation and minimizing energy consumption during low-demand periods, this model significantly lowers electricity bills. This feature aligns with the growing emphasis on sustainability in various sectors, allowing businesses to reduce their carbon footprint.

In terms of user-friendly attributes, the KF220TZG00 features an intuitive digital interface. The display is designed for easy navigation, enabling operators to make adjustments and monitor system performance without requiring extensive training. Additionally, it offers remote monitoring capabilities through internet connectivity, providing users with the flexibility to manage systems from virtually anywhere.

Durability is another characteristic that enhances the appeal of the KF220TZG00. Built with robust materials, it can withstand challenging environmental conditions, making it suitable for a wide range of applications, from commercial refrigeration to industrial processing. The device is also designed to provide long service life, reducing the need for frequent replacements and maintenance.

Moreover, the KF220TZG00 supports various communication protocols, allowing it to integrate seamlessly with existing control systems. This interoperability makes it an ideal choice for businesses looking to upgrade their equipment without overhauling their entire system.

In summary, the Emerson KF220TZG00 is a sophisticated temperature control solution that excels in accuracy, energy efficiency, user-friendliness, durability, and compatibility. These features make it a perfect choice for organizations aiming to enhance their operational efficiency while adhering to environmental and safety standards. Whether for commercial refrigeration or industrial climates, the KF220TZG00 stands out as a trustworthy and innovative solution.