location and function of controls
TENSION KNOB
ON/OFF SWITCH
GUARD LOCK KNOBS | BLADE | HOLDER |
| RETAINING | CLIPS |
GUARD | BLOWER |
|
| TUBE | ]OLDERS |
|
| BLADE HOLDER |
|
| POCKETS |
BEVEL
SCALES
TABLEI
INSERT MITER GAUGE
BEVELLOCK KNOB
LOCK KNOB
BLADE STORAGE
motor specifications and electrical requirements
This machine is equipped with a 1725 RPM motor it is wired for operation on
alternating current. (TOOL MUST NOT BE CONVERTED TO OPERATE ON 230 VOLT)
For replacement motor refer to parts list in this manual.
CONNECTING TO POWER SUPPLY OUTLET
If power cord is worn or'cut, or damaged in any way, have it replaced immediately
WARNING: IF NOT PROPERLY GROUNDED THIS POWER TOOL CAN CAUSE AN ELECTRICAL SHOCK PARTICULARLY WHEN USED IN DAMP
LOCATIONS CLOSE TO PLUMBING. IF AN ELECTRICAL SHOCK OCCURS THERE IS THE POTENTIAL OF A SECONDARY HAZARD SUCH
AS YOUR HANDS CONTACTING THE SAW BLADE,
If you are not sure that your outlet, as pictured below, is properly grounded, have it checked by a
qualified efectrician
Your unit is for use on
This power tool is equipped with a 3=conductor cord and grounding type plug which has been approved by Underwriters' Laboratories and the Canadian Standards Association.. The ground conductor' has a
green jacket and is attached to the tool housing at one end and to the ground prong in the attachment
plug at the other'end
WARNING: DO NOT PERMIT FINGERS TO
TOUCH THE TERMINALS OF PLUGS WHEN INSTALLING OR REMOVING THE PLUG TO OR FROM THE OUTLET.
PROPERLY
GROUNDED
OUTLET
GROUNDING PRONG
Plug power cord intoa
tool is of the 2 prong type, DO NOT REMOVE OR
ALTER THE GROUNDING PRONG tN ANY MANNER Use an adapter as shown below and always connect the grounding lug to known ground
It is recommended that you have a qualified electrician replace the TWO prong outlet with a properly grounded THREE prong outlet
GROUNDING LUG
ADAPTER |
|
| MAKE SURE THIS IS |
TO A | |
PLUG | KNOWN GROUND |
| 2*PRONG |
| RECEPTACLE |
An adapter as illustrated is available for connecting plugs to
WARNING: THE GREEN GROUNDING LUG
EXTENDING FROM THE ADAPTER MUST BE
CONNECTED TO A PERMANENT GROUND SUCH AS TO A PROPERLY GROUNDED OUTLET BOX. NOT ALL OUTLET BOXES ARE PROPERLY GROUNDED.
If you are not sure that your outlet box is properly grounded, have it checked by a qualified electrician
NOTE: The adapter illustrated is for use only if you
already have a properly grounded
The use of any extension cord will cause some loss of power. To keep this to a minimum and to prevent
Use only 3 wire extension cords which have
grounding type plugs and
Extension Cord Length | Wire Size AWG | |
ft. | 16 | |
ft. | 14 | |
ft, | 12 |