Emerson CF955WW 00, CF955BS 00 Trouble Shooting, Trouble Probable Cause Suggested Remedy

Page 9

! WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting

TROUBLE

 

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

 

1. Fan will not start.

1.

Fuse or circuit breaker blown.

1.

Check main and branch circuit fuses or circuit breakers.

 

2.

Loose power line connections to the fan, or loose

2.

Check line wire connections to fan and switch wire

 

 

switch wire connections in the switch housing.

 

connections in the switch housing.

 

 

 

!

WARNING: Make sure main power is turned off.

 

3.

The remote control transmitter battery needs

3.

Check that the remote transmitter battery is in good

 

 

replacement.

 

condition; the red indicator will illuminate when the key

 

 

 

 

pad buttons are depressed.

 

 

 

 

 

2. Fan sounds noisy.

1.

Blades not attached to fan.

1.

Attach blades to fan before operating.

 

2.

Screws securing fan blade flanges to motor are

2.

Check to make sure the screws which attach the fan

 

 

loose.

 

flanges to the motor are tight.

 

3.

Screws holding blades to flanges are loose.

3.

Tighten screws securely.

 

4.

Glass bowl loose.

4.

Tighten the glass bowl securely.

 

 

 

 

 

3. Fan wobbles

1.

Setscrew in motor coupling is loose.

1.

Raise coupler cover and tighten the setscrew securely.

excessively.

2.

Setscrew in hanger ball/downrod assembly is

2.

Tighten the setscrew in the hanger ball/downrod assembly.

 

 

loose.

 

 

 

3.

Screws securing fan blade flanges to motor are

3.

Check to be sure screws which attach the fan blade

 

 

loose.

 

flanges to the motor are tight.

 

4.

Fan blade flanges not seated properly.

4.

Check to be sure the fan blade flanges seat firmly and

 

 

 

 

uniformly to the surface of the motor. If flanges are

 

 

 

 

seated incorrectly, loosen the flange screws and retighten

 

 

 

 

according to the procedure in the section on "How to Put

 

 

 

 

Your Ceiling Fan Together".

 

5.

Hanger bracket and/or ceiling outlet box is not

5.

Tighten the hanger bracket screws to the outlet box,

 

 

securely fastened.

 

and/or secure outlet box.

 

6.

Fan blades out of balance.

6.

Interchanging an adjacent (side-by-side) blade pair can

 

 

 

 

redistribute the weight and result in smoother operation.

 

 

 

 

 

4. All four lamps will not

1.

The remote control transmitter battery needs

1.

Replace the 12 V battery; recommended replacement

illuminate.

 

replacement.

 

12V batteries are Duracell MN21, Eveready A23, and

 

 

 

 

GP23A.

 

 

 

!

WARNING: Make sure main power is turned off.

 

2.

The 1.0 amp lamp fuse may have blown and

2.

Replace the 1.0 amp fuse with Emerson repair part

 

 

and needs replacement.

 

item 19. See page 5 and reverse the lower housing

 

 

 

 

installation instructions to gain access to the fuse holder.

 

 

 

 

 

9

U.L. Model No.: CF955

Image 9
Contents CF955BS Safety Instructions Unpacking Instructions Three wire connectors supplied One 3/16 hex wrench suppliedCheck to see that you have received the following parts ProceedingHow to Put Your Ceiling Fan Together Electrical Requirements How to Hang Your Ceiling FanWire Listed How to Wire Your Ceiling FanSetting Remote Control Operating Frequency Preset Memory FeatureInstalling Lamps Glass Globe Replacement batteries for transmitterProgramming the Ceiling Fan Receiver Operation of Your Remote ControlTrouble Probable Cause Suggested Remedy Trouble ShootingMaintenanceAccessories For your Ceiling FanDownrod Extension Kits see store or catalog Repair Parts Key Model Numbers Description Repair Parts Listing