Troubleshooting Procedures
This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified electrician should correct all electrical problems. For warranty service, contact your dealer or wholesale distributor.
Troubleshooting the Bath System
Symptoms | Probable Causes | Recommended Action | ||
1. User keypad does not | A. | No power to control. | A. | Check wiring and connect power. |
illuminate when power |
|
|
|
|
button is pressed or the |
|
|
|
|
outer ring is rotated. |
|
|
|
|
| B. | B. | Reset GFCI or RCD. If it trips | |
|
| (GFCI) or Residual Current |
| again, refer to |
|
| Device (RCD) tripped. |
| |
|
|
|
| Residual Current Device (RCD) |
|
|
|
| trips when unit is turned on.″ |
| C. | Wiring harness from user | C. | Check wiring for proper |
|
| keypad to control is loose, |
| connections. Replace the wiring |
|
| disconnected or damaged. |
| harness if necessary. Refer to your |
|
|
|
| installer or wholesale dealer. |
| D. User keypad does not work. | D. Replace the user keypad. Refer to | ||
|
|
|
| your installer or wholesale dealer. |
| E. | Control does not work. | E. | Replace the control. Refer to your |
|
|
|
| installer or wholesale dealer. |
2. | A. | Electrical harness is wet or | A. | Check for wet connections. Dry the |
| damaged. |
| connections and repair the leak. | |
or Residual Current |
|
|
| Check for insulation or connector |
Device (RCD) trips when |
|
|
| damage. Replace the harness if |
unit is turned on. |
|
|
| damaged. Refer to your installer or |
|
|
|
| wholesale dealer. |
| B. | Electrical wiring to the junction | B. | Have a qualified electrician |
|
| box is wet or damaged. |
| diagnose and correct the problem |
|
|
|
| in accordance with applicable |
|
|
|
| building and electrical codes. |
| C. | Electrical wiring to the power | C. | Have a qualified electrician |
|
| cord is wet or damaged. |
| diagnose and correct the problem |
|
|
|
| in accordance with applicable |
|
|
|
| building and electrical codes. |
| D. Blower motor does not work. | D. Replace the blower motor. Refer to | ||
|
|
|
| your installer or wholesale dealer. |
|
|
|
|
|