Garantía (cont.)
5.It is recommended that the consumer save the invoice or receipt as additional protection, as it may substitute the warranty in the case that there is a discrepancy in the validity of the warranty.
EXCEPTIONS AND RESTRICTIONS
The Warranty will not be valid in the following cases:
1.When the product is not operated in accordance with the instructions concerning use and operation set forth in the owner’s manual or installation instructions, and when the recommendations and warnings included are not observed.
2.When the product has been modified or dismantled partially or totally; or has been used in a negligent fashion and as a consequence has suffered damages attributable to the consumer, individual, or hardware not authorized by Kohler Co.
3.This warranty does not cover the damages as a result of disaster such as fire or acts of God, including flooding, earthquake, or electric storms, etc. To obtain a list of distributors in your area where you can exercise your rights under this warranty, please call
KOHLER CO., KOHLER, WI 53044 U.S.A.
IMPORTER:
INTERNACIONAL DE CERÁMICA, S.A.B. DE C.V.
AV. CARLOS PACHECO NO. 7200
CHIHUAHUA, CHIH., MEXICO C.P. 31060
TEL: 52 (14)
Procedimientos para resolver problemas
Esta guía para resolver problemas está diseñada únicamente como ayuda general. Todos los problemas eléctricos deben ser resueltos por un representante de servicio autorizado de Kohler o un electricista calificado. Para obtener servicio cubierto por la garantía, póngase en contacto con el vendedor o el distribuidor mayorista.
Guía para resolver problemas del sistema de la bañera
Síntomas | Causas probables | Acción recomendada | ||
1. El teclado no se ilumina | A. | El control no tiene alimentación | A. | Verifique el cableado y conecte el |
cuando se oprime el |
| eléctrica. |
| suministro eléctrico. |
botón de encendido o se |
|
|
|
|
gira el anillo externo. |
|
|
|
|
| B. | El interruptor de circuito con | B. | Oprima el botón de restablecer el |
|
| pérdida a tierra (GFCI) o el |
| interruptor GFCI o RCD. Si se |
|
| dispositivo de corriente residual |
| dispara otra vez, consulte ″El |
|
| (RCD) se ha disparado. |
| interruptor de circuito con pérdida |
|
|
|
| a tierra (GFCI) o el dispositivo de |
|
|
|
| corriente residual (RCD) se dispara |
|
|
|
| cuando la unidad se enciende″. |
| C. | El arnés de cables del teclado al | C. | Revise que los cables estén |
|
| control está suelto, desconectado |
| correctamente conectados. |
|
| o dañado. |
| Reemplace el arnés de cables de ser |
|
|
|
| necesario. Consulte al instalador o |
|
|
|
| distribuidor mayorista. |
| D. El teclado no funciona. | D. Reemplace el teclado. Consulte al | ||
|
|
|
| instalador o distribuidor mayorista. |
| E. | El control no funciona. | E. | Reemplace el control. Consulte al |
|
|
|
| instalador o distribuidor mayorista. |
|
|
|
|
|
Kohler Co. |