Troubleshooting Procedures (cont.)

Symptoms

Probable Causes

Recommended Action

13.

Noise level from pump

A. The check valve is

A.

Tap the check valve with a

 

has increased and/or

malfunctioning.

 

screwdriver handle. Restart the

 

airjet performance has

 

 

system. If the symptoms have

 

decreased.

 

 

ceased, the check valve does not

 

 

 

 

need to be replaced.

 

 

B. The check valve needs to be

B.

Remove the check valve from the

 

 

replaced.

 

check valve assembly. Reassemble

 

 

 

 

the check valve assembly without

 

 

 

 

the check valve. Restart the system.

 

 

 

 

If the system properly functions

 

 

 

 

without the check valve, the check

 

 

 

 

valve needs to be replaced. For

 

 

 

 

safety, reinstall the malfunctioning

 

 

 

 

check valve until a replacement

 

 

 

 

check valve can be installed.

 

 

 

 

For Baths with Chromatherapy

 

 

 

 

 

Symptoms

Probable Causes

Recommended Action

14.

Chromatherapy lights do

A. Loose, disconnected or damaged

A.

Check wiring for proper

 

not work.

wiring/connections.

 

connections. Replace wiring if

 

 

 

 

necessary. Refer to your installer or

 

 

 

 

wholesale dealer.

 

 

B. Control does not work.

B.

Replace control. Refer to your

 

 

 

 

installer or wholesale dealer.

 

 

 

 

 