!WARNING

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

3/16-24 x 1/4" SLOTTED PHILLIPS SCREWS (3)

BLADE WASHERS (3)

 

FAN BLADE

Figure 5

BLADE FLANGE

NOTE: Take care not to scratch fan housing when installing blades.

9.Turn the fan assembly upside down in preparation for mounting the fan blade assemblies.

NOTE: Remove and discard the four shipping spacers and screws from the motor hub.

10.Rotate the motor hub until the flange screw hole is next to the cutout in the switch housing plate. Loosely attach one blade assembly to the motor hub using two 1/4-20 x 1/2” Phillips oval head flange screws. Make sure the screws are NOT tightened. (Figure 6.) Repeat this procedure for the other four blade assemblies.

SWITCH HOUSING

ASSEMBLY

SWITCH HOUSING

CONNECTOR

MOTOR

CONNECTOR

SWITCH HOUSING

MOUNTING SCREW (3)

Figure 7

13.Remove the three switch housing mounting screws (Figure 7) from the switch housing plate. Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three mounting screws (Figure 8).

NOTE: Do not pinch wires between the switch housing assembly and the switch housing plate.

SWITCH HOUSING

ASSEMBLY

SWITCH HOUSING

MOUNTING SCREW (3)

Figure 8

 

BLADE

SWITCH

FLANGE

HOUSING

 

PLATE

 

14. You have now completed the assembly of your new ceiling fan. You can now proceed with hang- ing and wiring your fan.

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

Figure 6

1/4-20 x 1/2" PHILLIPS OVAL HEAD FLANGE SCREW (2)

MOTOR HUB

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan

11.The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the flange screws in a clockwise sequence. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws, re-engage and reseat the flanges, then tighten the screws again.

12.Engage the connector of the switch housing assembly with the motor connector (Figure 7). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the con- nector latch closes properly.

5

support and may need to be replaced. Consult a qualified electrician in in doubt.

The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

!WARNING

To avoid fire or shock, follow all wiring instructions carefully.

Any electrical work not described in these instruc- tions should be done or approved by a licensed electrician.

Image 5
Contents Zurich Date Code Safety InstructionsUp to 50 ft 50-100 ft Unpacking InstructionsThat are 80-inches long. Before installing the fan How to Put Your Ceiling Fan TogetherHanger ball/downrod assembly. Cut off excess Fan comes with blue, black and white leadsElectrical Requirements How to Wire Your Ceiling Fan How to Hang Your Ceiling FanMaintenance Using Your Ceiling FanAccessories THREE-SPEEDHOW to Order Repair Parts Trouble ShootingRepair Parts Listing