!WARNING
To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
BLADE WASHERS (3)
| FAN BLADE |
Figure 5 | BLADE FLANGE |
NOTE: Take care not to scratch fan housing when installing blades.
9.Turn the fan assembly upside down in preparation for mounting the fan blade assemblies.
NOTE: Remove and discard the four shipping spacers and screws from the motor hub.
10.Rotate the motor hub until the flange screw hole is next to the cutout in the switch housing plate. Loosely attach one blade assembly to the motor hub using two
SWITCH HOUSING
ASSEMBLY
SWITCH HOUSING
CONNECTOR
MOTOR
CONNECTOR
SWITCH HOUSING
MOUNTING SCREW (3)
Figure 7
13.Remove the three switch housing mounting screws (Figure 7) from the switch housing plate. Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three mounting screws (Figure 8).
NOTE: Do not pinch wires between the switch housing assembly and the switch housing plate.
SWITCH HOUSING
ASSEMBLY
SWITCH HOUSING
MOUNTING SCREW (3)
Figure 8
| BLADE |
SWITCH | FLANGE |
HOUSING |
|
PLATE |
|
14. You have now completed the assembly of your new ceiling fan. You can now proceed with hang- ing and wiring your fan.
Electrical Requirements
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
Figure 6
MOTOR HUB
!WARNING
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan
11.The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the flange screws in a clockwise sequence. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws,
12.Engage the connector of the switch housing assembly with the motor connector (Figure 7). The two connectors are keyed and
5
support and may need to be replaced. Consult a qualified electrician in in doubt.
The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds.
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
!WARNING
To avoid fire or shock, follow all wiring instructions carefully.
Any electrical work not described in these instruc- tions should be done or approved by a licensed electrician.