Emerson CF929WW 00, CF929BS 00 owner manual Additional Safety Instructions for Installation

Page 2

!WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

5.Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.All wiring must satisfy National and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as acceptable for fan support, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling.

5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Company could result in personal injury or property damage.

WARNING: To Reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label.

You should record this data above and keep it in a safe place for future use.

2

Image 2
Contents Midway Safety Instructions Additional Safety Instructions for InstallationCheck to see that you have received the following parts Unpacking InstructionsUp to 50 ft 50-100 ft How to Put Your Ceiling Fan Together How to Hang Your Ceiling Fan Electrical RequirementsHow to Wire Your Ceiling Fan Hanger bracketSetting Remote Control Operating Frequency Installing Glass GlobePreset Memory Feature Setting Transmitter FrequencySetting Receiver Frequency Using Your Ceiling FanOperation of Your Remote Control Trouble Shooting Trouble Probable Cause Suggested RemedyMaintenanceAccessories Downrod Extension Kits see store or catalogRepair Parts Repair Parts Listing

CF929WW 00, CF929BS 00 specifications

The Emerson CF929BS and CF929WW ceiling fans are exemplary models that combine functionality with aesthetic appeal, making them ideal choices for both modern and traditional home decor. These fans are specially crafted with sleek designs and innovative technologies that stand out in the market.

One of the main features of the Emerson CF929 series is its powerful yet efficient motor. The fans are equipped with a robust motor that provides excellent airflow, effectively cooling spacious rooms while consuming minimal electricity. This energy efficiency is significant for homeowners looking to reduce their energy bills while maintaining comfort.

The CF929BS model comes in a striking brushed steel finish, while the CF929WW variant features a classic white color, offering versatile options for various interior styles. Both models are designed with a contemporary silhouette that complements a range of decorative themes, from modern minimalism to rustic charm.

Installation is made easy with the included downrod, which allows the fan to be hung at the optimal height for effective air distribution. Additionally, both models can be paired with a compatible remote control, allowing users to adjust settings such as speed and lighting from the comfort of their seat.

Versatility is another strong selling point of the Emerson CF929 series. These fans are equipped with a reversible motor, enabling users to change the airflow direction. In the summer, the fan circulates cool air downward, while in the winter, it reverses to create an updraft that helps distribute warm air, ensuring comfort all year round.

The CF929 fans also feature integrated LED lighting, providing bright and efficient illumination. The bulbs are long-lasting, and the fixture design allows for even light distribution, making them perfect for use in living rooms, bedrooms, or dining areas.

Another noteworthy characteristic is the quiet operation. The fans are designed to operate silently, allowing for a peaceful environment free from bothersome noises.

In summary, the Emerson CF929BS and CF929WW ceiling fans showcase a blend of style, technology, and performance. With their energy-efficient motors, stylish finishes, remote control compatibility, and versatile airflow options, they are exceptional additions to any home looking to enhance comfort and elegance.