Hobart Welding Products 250 Principal Safety Standards, EMF Information, About Pacemakers

Page 8

1-5. Principal Safety Standards

Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

Recommended Safe Practices for the Preparation for Welding and Cut- ting of Containers and Piping, American Welding Society Standard AWS F4.1 from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

National Electrical Code, NFPA Standard 70, from National Fire Protec- tion Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269−9101 (phone: 617−770−3000, website: www.nfpa.org).

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1735 Jefferson Davis Highway, Suite 1004, Arlington, VA 22202−4102 (phone: 703−412−0900, web- site: www.cganet.com).

Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale

Boulevard, Rexdale, Ontario, Canada M9W 1R3 (phone: 800−463−6727 or in Toronto 416−747−4044, website: www.csa−in- ternational.org).

Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute, 11 West 42nd Street, New York, NY 10036−8002 (phone: 212−642−4900, website: www.ansi.org).

Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, NFPA Standard 51B, from National Fire Protection Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269−9101 (phone: 617−770−3000,website: www.nfpa.org).

OSHA, Occupational Safety and Health Standards for General Indus- try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Super- intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (there are 10 Regional Offices−−phone for Region 5, Chicago, is 312−353−2220,website: www.osha.gov).

1-6. EMF Information

Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields

Welding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power- frequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.

To reduce magnetic fields in the workplace, use the following procedures:

1.Keep cables close together by twisting or taping them.

2.Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep welding power source and cables as far away from opera- tor as practical.

5.Connect work clamp to workpiece as close to the weld as possi- ble.

About Pacemakers:

Pacemaker wearers consult your doctor before welding or going near welding operations. If cleared by your doctor, then following the above procedures is recommended.

OM-192 440 Page 4

Image 8
Contents OM-192 440W ProcessesDescription File MIG GmawFrom Hobart to You Table of Contents Warranty Symbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Indique un message de sécurité particulier UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux LE Soudage peut provoquer un Incendie ou une explosionDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesRisque D’INCENDIE OU D’EXPLO LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sécurité En ce qui concerne les stimulateurs cardiaquesSpecifications Welding Power Source Duty Cycle And OverheatingExceeding duty cycle can damage unit and void warranty OverheatingDefinition Welding Gun Duty Cycle And OverheatingVolt-Ampere Curves Installing Welding Gun Connecting To Weld Output Terminals Installing Work ClampSetting Gun Polarity For Wire Type Installing Wire Spool And Adjusting Hub TensionInstalling Gas Supply Rear PanelPositioning Jumper Links VoltsElectrical Service Guide Hz SingleInput Voltage Min Grounding Conductor Size In AWGSelecting a Location And Connecting Input Power Threading Welding Wire WoodTurn Off unit, and disconnect input power OperationConnecting Spool Gun To Welding Power Source Turn Off unit− Operation ControlsWhile welding Voltage switch positionWeld Parameters Number on left of slash To read settingsExample 2/40 = Routine Maintenance Disconnect power before maintainingSupplementary Protectors MonthsRemoving Knob From Front Panel Replacing Drive Roll And Wire Inlet GuideTurn Off power Turn Off power before replacing contact tip Replacing Gun Contact TipTurn off welding power source/wire feeder Wire size stamped on tip − check and match wire sizeReplacing Switch And/Or Head Tube Welding Troubleshooting Table Wire Drive/Gun Troubleshooting TableWire Drive/Gun Trouble Remedy Welding Trouble Remedy− MIG Welding Gmaw Guidelines Typical MIG Process ConnectionsTypical MIG Process Control Settings Wire Size Amperage RangeThickness to Amperage a AmperageHolding And Positioning Welding Gun Conditions That Affect Weld Bead Shape Gun Movement During Welding Poor Weld Bead CharacteristicsGood Weld Bead Characteristics Troubleshooting − Excessive Spatter Troubleshooting − PorosityTroubleshooting − Excessive Penetration Possible Causes Corrective ActionsTroubleshooting − Burn-Through Troubleshooting − Lack Of PenetrationTroubleshooting − Incomplete Fusion Troubleshooting − Waviness Of Bead Troubleshooting − DistortionTroubleshooting Guide For Semiautomatic Welding Equipment Wire does not feedCommon MIG Shielding Gases ApplicationWelding arc not stable Wire slipping in drive rolls OM-192 440 − Electrical Diagram − Parts List REGULATOR/FLOWMETER, 10−50 CFH ARGON/CO2 Center Baffle w/Components Center Baffle w/Components -1Item Rear Panel w/Components Front Panel w/Components M-25 Gun Optional Spool Gun Switch Description RemarksPage Assistance ServiceSupport Contact your Distributor for Hobart Welding Products